Second encoder axis for i950 drive
On i950 drives, the position value from the second encoder slot can be used as described in the following sections.
i950-CiA402 Inverter
The encoder node provides the following parameters on the tabs:
- Scaling
- Filter function
- Switching between modulo and linear axis
Additionally, after power-on, a position reconstruction could be achieved on the encoder node by configuring the motion parameters (subindex 81 / subindex 82 ) of the encoder node.
Connecting the second encoder via the system bus EtherCAT to the PLC (CiA402 device profile):
- Attach encoder to the i950 node via "Attach Device"
- The second encoder node is then displayed under the i950 device.
- Next, parameter 16#60E4:01 must be included in the PDO mapping of the i950 device..
- The encoder can now be used in the PLC, e. g. for position control.
i950 Inverter with active technology application
Parameterization is carried out in the corresponding technology application by performing the following steps:
1. Connect and parameterize the load encoder (see chapter "Second feedback system for the techology application")
2. Set scaling correctly (see chapter "Kinematics settings" and chapter "Position Control")
3. If necessary, switch the actual value source of the position control to the load encoder (0x500D:90 and 0x500D:91 for a CiA-Advanced application or 0x500A:090 and 0x500A:091 for a technology application)
-
By closing the position control loop in the technology application, the control loop has lower delay times, allowing higher gain factors to be achieved.