Homing

The zero point in the machine measuring system can be defined by the FB MC_Home , the FB MC_SetPosition or via the corresponding function of the FB L_MC1P_AxisBasicControl .

  • If the UseAuxHomeParameter input of the FB MC_Home is set to FALSE, the following parameters are used for homing.

  • Detailed information for homing can be found in the description of the FB MC_Home .

  • The information that the axis is referenced is provided at the FB MC_ReadAxisInfo and the FB L_MC1P_AxisBasicControl via the xIsHomed output.

  • The FB L_MC1P_ResetHomePosition serves to reset the "reference known" status.

  • With the help of modes 97 and 98, the reference can be set to any state of the axis (as when using the FB MC_SetPosition )

When using an external position encoder, please observe the notes in the Position controller section.

Subchapter: