Homing
The zero point in the machine measuring system can be defined by the FB MC_Home , the FB MC_SetPosition or via the corresponding function of the FB L_MC1P_AxisBasicControl .
-
If the UseAuxHomeParameter input of the FB MC_Home is set to FALSE, the following parameters are used for homing.
-
Detailed information for homing can be found in the description of the FB MC_Home .
-
The information that the axis is referenced is provided at the FB MC_ReadAxisInfo and the FB L_MC1P_AxisBasicControl via the xIsHomed output.
-
The FB L_MC1P_ResetHomePosition serves to reset the "reference known" status.
-
With the help of modes 97 and 98, the reference can be set to any state of the axis (as when using the FB MC_SetPosition )
When using an external position encoder, please observe the notes in the
Position controller
section.