Homing Mode (subindex 70 )

Virtual axis Encoder 9400 HighLine i700 servo inverter i500 inverter i950 servo inverter

Homing mode

Selection list (Lenze setting printed in bold)

Info

-2

CwTorqueLimit

-1

CcwTorqueLimit

0

SetPositionDirect

Directly set reference
  • Same function as MC_SetPosition without movement of the axis.
  • SetPositionDirect

1

CcwLimitSwitchCwTP

Negative direction - reversing to limit switch - to touch probe
  • CcwLimitSwitchCwTP

2

CwLimitSwitchCcwTP

Positive direction - reversing to limit switch - to touch probe
  • CwLimitSwitchCcwTP

3

CwRpCcwRnTP

Positive direction - reversing to reference switch - to touch probe
  • CwRpCcwRnTP

5

CcwRpCwRnTP

Negative direction - reversing to reference switch - to touch probe
  • CcwRpCwRnTP

17

CcwLimitSwitch

Negative direction to limit switch
  • CcwLimitSwitch

18

CwLimitSwitch

Positive direction to limit switch
  • CwLimitSwitch

19

CwRpCcwRn

Positive direction - reversing to reference switch - negative edge of reference switch
  • CwRpCcwRn

21

CcwRpCwRn

Negative direction - reversing to reference switch - negative edge of reference switch
  • CcwRpCwRn

33

CcwTP

Negative direction to touch probe
  • CcwTP

34

CwTP

Positive direction to touch probe
  • CwTP

97

SetPositonInAnyState

Set reference position directly, independent of the state of the axis
  • (also with controller inhibit or a movement)
  • SetPositionInAnyState

98

SetOffsetInAnyState

Set reference offset directly, independent of the state of the axis
  • (also in case of controller inhibit or a movement)
  • SetOffsetInAnyState

99

ResetHomeInfo

The "Reference known" state is reset
  • ResetHomeInfo

100

DriveBased

Use homing mode of the drive
  • The homing mode to be used in the drive can be configured in subindex 83, provided it is supported by the drive.
  • DriveBased

Read access Write access Can only be changed in "Disabled" state No download

SIGNED_16

The general error message "Home_WriteHomeParameter" is generated, if the selected homing mode is not supported by the drive

  • Solution: Use a Referencing mode supported by the inverter (see the documentation of the inverter).