Standard values
The following parameters can be used to set standard values for velocity, acceleration, and jerk.
-
The set standard values are used if the value "0" is applied to the input of an FB for the respective amount or the input has not been interconnected.
-
The set standard values are used for point-to-point motions in the robotics (MC_MoveDirect...) as well.
-
Application example: An identical jerk should always be used. In this case, it is not necessary to specify the jerk at all motion-activating FBs via the Jerk input. Instead, you can set and change the jerk globally in subindex 43 for the motion axis.
-
Special case: Standard jerk = 0 --> linear ramp