With this function, the following control parameters can be optimised using automated procedures:
- Speed controller gain (0x2900:001)
- Speed controller reset time (0x2900:002)
- Position controller gain (0x2980)
- Position controller gain (subindex 93 of AXIS_REF)
After successful optimisation, the determined parameter values must still be saved manually in the storage medium in a way that is safe from mains failure (save parameter set must be executed). Saving control parameters persistently
- Supported topologies:
- i950 TA (from firmware version v1.6) via EasyStarter c1.20,
- i950 PLC (from firmware version v1.6) via PLCDesigner v3.23,
- i950 Base (from firmware version v1.6) via PLCDesigner v3.23,
- i700 (from firmware version v2.16) via PLCDesigner v3.23
- Supported cycle times: 1 - 4 ms
|
Note!
The Autotuning function can only be started in the "Disabled" axis state, i.e. the axis is inhibited and error-free. After the start, there is a change to the axis state "Service". In this state, the drive is automatically enabled for the execution of the function. The execution can be aborted prematurely via:
The abort results in the drive being inhibited again. |
The function can be started via the AxisRef parameter Subindex 170 = [1] ("Perform Autotuning"). Subsequently, the following states are run through in sequence and displayed in the object subindex 177 ("Autotuning: State"):
After successful completion of the optimization, one of the following states is displayed in object subindex 177 ("Autotuning: State"):
Function aborted by the user via object subindex 170 = [1] "Abort":
Subindex 177 then changes to the "User abort" state (Subindex 177 = [9] "User abort").
Function abort due to an error that has occurred:
- The drive is brought to a standstill via a speed-controlled stop ramp.
- The values saved in the "Save parameters" state (subindex 177 = 2) are written back to the objects.
Parameter list for controlling the function in the AxisRef data structure:
Perform auto-tuning (subindex 170)
|
|
|||||||||||
|
Selection list (Lenze setting printed in bold) |
|
||||||||||
|
0 |
Off/Ready |
||||||||||
|
1 |
On/start |
||||||||||
|
2 |
In progress |
||||||||||
|
3 |
Action cancelled |
||||||||||
|
4 |
No access |
||||||||||
|
5 |
No access (disabled) |
||||||||||
|
16 |
Abort |
||||||||||
|
20 |
20% |
||||||||||
|
40 |
40% |
||||||||||
|
60 |
60% |
||||||||||
|
80 |
80% |
||||||||||
|
101 |
Taskcycle > 4ms |
||||||||||
|
102 |
STO active |
||||||||||
|
103 |
Invalid settings |
||||||||||
|
104 |
Version not supported |
||||||||||
|
105 |
Distance to long |
||||||||||
|
106 |
0x2824 = Off [0] |
||||||||||
|
107 |
Temporary not available |
||||||||||
|
|
UNSIGNED_8 |
||||||||||
Auto-tuning: Maximum speed (subindex 171)
|
|
|||||||||||
|
Setting range (min. value | unit | max. value) |
Lenze setting |
||||||||||
|
0 |
Unit/s |
2147483647 |
0 Unit/s |
||||||||
|
|
FLOAT_64 |
||||||||||
Auto-tuning: Maximum acceleration (subindex 172)
|
|
|||||||||||
|
Setting range (min. value | unit | max. value) |
Lenze setting |
||||||||||
|
0 |
Unit/s² |
2147483647 |
0 Unit/s² |
||||||||
|
|
FLOAT_64 |
||||||||||
Auto-tuning: Maximum distance (subindex 173)
|
|
|||||||||||
|
Setting range (min. value | unit | max. value) |
Lenze setting |
||||||||||
|
0 |
Unit |
2147483647 |
0 Unit |
||||||||
|
|
FLOAT_64 |
||||||||||
Auto-tuning: Min. sug. distance (subindex 174)
|
|
|||||||||||
|
Display area (min. value | unit | max. value) |
Initialization |
||||||||||
|
0 |
Unit |
2147483647 |
0 Unit |
||||||||
|
|
FLOAT_64 |
||||||||||
Auto-tuning: State (subindex 177)
|
|
|||||||||||
|
Selection list (Lenze setting printed in bold) |
|
||||||||||
|
0 |
Disabled |
||||||||||
|
1 |
Initialization |
||||||||||
|
2 |
Backup parameter |
||||||||||
|
3 |
Checking preconditions |
||||||||||
|
4 |
Autotune speed controller gain |
||||||||||
|
5 |
Autotune speed controller reset time |
||||||||||
|
6 |
Autotune postion controller gain |
||||||||||
|
7 |
Abort function |
||||||||||
|
8 |
Abort by error |
||||||||||
|
9 |
Abort by user |
||||||||||
|
10 |
Finished - improved performance |
||||||||||
|
11 |
Finished - identic performance |
||||||||||
|
12 |
Finished - stability margin increased |
||||||||||
|
|
UNSIGNED_16 |
||||||||||