Dead time compensation

The actual values transmitted by the encoder are influenced by dead time in the encoder axis after signal transmission. To compensate for this dead time, it is possible to extrapolate the actual values provided by the encoder axis.

Dead time compensation can be activated in subindex 67 .

With a master-slave coupling in an i950 servo inverter used as an (EtherCAT) master, it is still possible to delay the setpoint generated for the master: With subindex 67 = 1 a precise position or speed synchronisation to the connected slave axes is achieved.