Software limit positions
The parameterisable limit positions serve to limit the traversing range by the software.
Evaluation and monitoring of the software limit positions are only carried out if
-
the drive knows the home position,
-
the software limit positions are activated via subindex 50 and
-
monitoring has not been deactivated from the application.
In case of the "Modulo" traversing range and in the device states "Homing", "ErrorStop" and "Disabled", the software limit positions are usually not active.
-
The information that monitoring of the software limit positions is really effective is provided at the FB MC_ReadAxisInfo and FB L_MC1P_AxisBasicControl via the xSWLimitEnabled output.
-
From the application, monitoring of the software limit positions can be deactivated via the following FBs (temporarily):
-
FB L_MC1P_AxisBasicControl : Set xDisableSWLimit input to TRUE.
-
FB L_MC1P_DisableSWLimit : Set xEnable input to TRUE.
-
When the SW limit position is exceeded, the system switches to the "ErrorStop" state. "Retraction" of the SW limit positions is possible in the direction of the permitted range. The desired error response can be configured in subindex 105 .
-
For motion control FBs which cause a change to the "ContinuousMotion" or "DiscreteMotion" state, the behaviour can be set in subindex 53 .
-
For FBs which switch the axis to the "SynchronizedMotion" state (e.g. MC_GearIn ), no check is carried out in advance. The axis is not stopped until the SW limit positions have been exceeded.