Default Jerk (subindex 43 )

Virtual axis Encoder 9400 HighLine i700 servo inverter i500 inverter i950 servo inverter

Default jerk
  • Standard jerk for positioning processes or MC_MoveDirect motions.
  • Special case: Standard jerk = 0 corresponds to a linear ramp. 'note'The set standard values are used if the value 0 is applied to the input of an FB for the respective amount, or the input has not been interconnected.'/note'

Setting range (min. value | unit | max. value)

Lenze setting

0

Unit/s³

2147483647

Read access Write access Can only be changed in "Disabled" state No download

FLOAT_64

If linear ramps are to be used for a movement (no active jerk limitation) and a value for the standard jerk is parameterised, the maximum value of 2147483647 Unit/s³ must be parameterised on the FB for the jerk.