Set area for grinding in

During the grinding-in process, the axis is moved in a range whose limits are defined as follows:

  • Limit1: negative limit

  • Limit2: positive limit

The range is not left during the loop-in. With Loop in brake: control word (parameter 142, bit 03) the source for the definition of the range is defined:

  • Loop in limitation by the SW end positions with Loop in brake: control word(parameter 142, bit 03) = FALSE

    • Limit 1: positive SW end position with parameter 51

    • Limit 2: negative SW end position with parameter 52

  • Loop in separate limitation with Loop in brake: control word(parameter 142, bit 03 = TRUE

    • Limit 1: negative limit with parameter 168 (lower position limit).

    • Limit 2: positive limit with parameter 169 (upper position limit).

 

  • If the set limits for brake application are outside the SW end positions, the SW end positions are used.

Further settings via the brake control word in parameter 142:

  • Bit 0: TRUE: The motor or brake is externally ventilated.

    The externally ventilated motor or the externally ventilated brake enables braking during the time-out. By reducing the speed, a shorter run-in distance is achieved.

  • Bit 1 = TRUE: End the grinding-in process in the starting position from which the function was started.

  • Bit 2 = TRUE: The reference position check is deactivated. Brake application also starts if the reference position (xIsHomed = FALSE) is not known.

  • Bit 3 = TRUE: The limit from parameters 168 and 169 are activated.

  • Bit 4 = TRUE: Brake application is executed in speed mode.

Function-relevant parameters

The parameters are located in the AxisRef.

Ein Bild, das Tisch enthält.

Automatisch generierte Beschreibung