In the Position operating mode (eOperationMode = 0: Position), the end positions are used as position values. The position values are read from the persistent data persistentVar : L_TW2P_PersistentVarTraverserBase.

The position values can be overwritten at any time:

  • With xLoadLowerPos = TRUE, the lower reversal position lrLowerPos is persisted.

  • With xLoadUpperPos = TRUE, the upper reversal position lrUpperPos is persisted.

Changes to the reverse positions are active immediately and are used directly for the work area.