L_IE1P_ForwardSeverity

This FB can be used to control the forwarding of errors from subordinate machine modules to the next level.

In addition, the visibility of errors of this module can be completely deactivated in the superimposed module.

If this FB is used with a module handler of the type "GeneralMachineModule" or "MachineModule", all errors of the subordinate machine modules are also visible in the next level and can be read with FB L_IE1P_ReadActualSeverity.

 

 

 

L_IE1P_ForwardSeverity

 

 

 

BOOL

–

 

xEnable

xBusy

 

–

BOOL

L_IMHP_IModuleHandler

–

 

ModuleHandler

xError

 

–

BOOL

BOOL

–

 

xForwardFromChildModules

eErrorID

 

–

L_IE1P_Error

BOOL

–

 

xDisableForwardToParent

eSeverity

 

–

L_IE1P_SeverityLevel

 

 

 

 

 

 

 

 

Inputs

Name

Datatype

Info/ setting options

xEnable

BOOL

TRUE

Activate readout of error information

Modulehandler

L_IMHP_IModuleHandler

Definition of the affiliation of error messages to a module.

When this input is connected, the errors generated for the module are displayed at the outputs.

If the input is not connected, an error is displayed at the FB output.

xForwardFromChildModules

BOOL

TRUE

Collect errors from subordinate machine modules (Componenttype = MachineModule or GeneralMachineModule) and make them visible for the parent module.

xDisableForwardToParent

BOOL

TRUE

All errors of the model and the subordinate machine modules (if xForwareFromChildModules=TRUE) are hidden for the superimposed parent module.

Outputs

Name

Datatype

Value/ Description

xBusy

BOOL

TRUE

The FB is processed

xError

BOOL

TRUE

An error occurred during the processing of the FB. Details see eErrorID .

eErrorID

L_IE1P_Error

If xError = TRUE: Error number for the error that occurred within the FB.

eSeverity

L_IE1P_Severity

Severity of the current error