L_IE1P_SetErrorSingle

This FB can be used to trigger / log an error with different severity levels.

When a fault is triggered

  • The error for the component connected via the Module Handler input is assigned.

  • the specified error response is executed in the component connected via the ErrorHandler input

  • Enumerations

  • the error in object 0x2010 is displayed

  • generates a logbook entry

For a description of the error number structure and the definition of the error texts, see

NOTE

Several errors with the same error ID must not be triggered at the same time for the connected ModuleHandler.

 

 

 

L_IE1P_SetErrorSingle

 

 

 

L_IMHP_IModuleHandler

–

 

ModuleHandler

xError

 

–

BOOL

L_IE1P_IErrorHandler

–

 

ErrorHandler

eErrorID

 

–

L_IE1P_Error

WORD

–

 

wTexRefID

scErrorInformation

 

–

L_IE1P_ErrorInfo

BOOL

–

 

xSetError

L_IE1P_SeverityLevel

–

 

eSeverity

WORD

–

 

wErrorId

L_IE1P_Reaction

–

 

eReaction

       

L_IE1P_Group

–

 

eGroup

       

 

 

 

 

 

 

 

 

Inputs

Name

Datentyp

Information/possible settings

ModuleHandler

L_IMHP_IModuleHandler

Defines the assignment of error messages to a module.

Functions can be grouped in the software by the ModuleHandler.

For example, certain functions can be assigned to machine modules. By connecting the ModuleHandler to the FB L_IE1P_SetError, the errors can be assigned to the machine module.

If the ModuleHandler input is not connected, the transmitted errors are assigned to the "Application" component.

Errorhandler

L_IE1P_IErrorHandler

Connection of the function block instance of a component in which the error reaction is to be executed.

The following types can currently be connected:

  • Motion axes (AXIS_REF)

  • Axes groups (Axes_Group)

  • FB L_IE1P_ErrorHandler (if no axis is present or the reaction is to be triggered in several components simultaneously)

wTextRefID

WORD

Text lists ID of the set error numbers

  • Only values between 0x3C00..0x3FFF permissible

  • The variable name of the ErrorManagement text list can also be created here.

If a 0 or 0x2C00 is specified, an error with the text list ID 0x2C00 is generated. This ID is reserved for Lenze. This means that the FAST

Motion error generated from the L_IE1P_Error enum

xSetError

BOOL

FALSE ä TRUE

Trigger errors with the properties attached to eSeverity, wErrorId, eReaction and eGroup.

TRUE

The triggered error cannot yet be acknowledged.

eSeverity

L_IE1P_SeverityLevel

Severity / error reaction of the error

wErrorID

WORD

16 Bit error event number

  • Only numbers > 0 are allowed
  • The event number must not be used simultaneously on the other wErrorID inputs.

eReaction

L_IE1P_Reaction

Reaction to be triggered with the error

This input is only evaluated for errors with the severities Warning,Warning_Lock, Fault_Log and Fault.

eGroup

L_IE1P_Group

Group membership of the error

By assigning an error to a group, these errors are made known to a certain group of users.

  • Die Filterung im Logbuch ist möglich.

Tip

Further information can be found in the section "Settings for the FAST_MachineErrorManager node" in the Lenze Engineering Tool "PLC Designer" customer manual.

Further information can be found in the description of the Lenze Engineering Tool "PLC Designer" :

Outputs

Name

Datentyp

Value/meaning

xError

BOOL

TRUE

An error has occured. For details see eErrorID .

Output or display of all errors occurring in the axis see xAxisError or eAxisErrorID .

eErrorID

L_IE1P_Error

If xError = TRUE: Error number for the error that occurred within the FB.

Reference Manual " FAST Technology Modules ":

Here you will find information on error or warning messages.

Note:

There is a distinction between:

  • FB errors ( eErrorID )
  • AXIS_REF errors ( eAxisErrorID )
  • Drive errors ( dwDriveErrorID )

scErrorInformation

L_IE1P_ErrorInfo

Status information that the error was triggered.