L_IE1P_ResetError

This FB can be used to request a reset of the acknowledgeable errors of the connected module handler and its subordinate modules. The output xResetActive signals that an error acknowledgement has just been requested somewhere.

Supported devices

i950

The error reset works globally, i.e. errors in other modules/ components are also reset.

c5x0

No limitation

32xxC

Limited functionality (the error reset is only performed in relation to the connected error handler.

 

 

 

L_IE1P_ResetError

 

 

 

L_IE1P_IModuleHandler

–

 

ModuleHandler

xError

 

–

BOOL

L_IE1P_IErrorHandler

–

 

ErrorHandler

eErrorID

 

–

L_IE1P_Error

BOOL

–

 

xResetError

xErrorResetActive

 

–

BOOL

       

xResetActive

 

–

BOOL

 

 

 

 

 

 

 

 

Inputs

Name

Datentyp

Information/possible settings

ModuleHandler

L_IE1P_IModuleHandler

Connection of the ModuleHandler for which the error is to be acknowledged. The errors of the stored modules are also acknowledged.

If the ModuleHandler input is not connected, the errors of the "Application" component are acknowledged.

The "Application" component contains error messages that were sent with an FB L_IE1P_SetError or L_IE1P_SetErrorSingle without a ModuleHandler connected.

Errorhandler

L_IE1P_IErrorHandler

Connection of the function block instance, a component in which the error reaction should be executed.

The following types can currently be connected:

  • Motion axes (AXIS_REF)

  • Axes groups (Axes_Group)

  • FB L_IE1P_ErrorHandler (if no axis is present or the reaction is to be triggered in several components simultaneously)

xResetError

BOOL

FALSE ä TRUE

Error reset for all acknowledgeable errors.

An error can only be reset if the triggering event is no longer pending, i.e., if input xSetEror is no longer TRUE for errors triggered by the application.

Outputs

Name

Datentyp

Value/meaning

xError

BOOL

TRUE

An error has occured. For details see eErrorID .

eErrorID

L_IE1P_Error

If xError = TRUE: Error number for the error that occurred within the FB.

Reference Manual " FAST Technology Modules ":

Here you will find information on error or warning messages.

xErrorResetActive

BOOL

TRUE

An error reset has been executed

xResetActive

BOOL

TRUE

An acknowledgement of the error (error reset) has been requested by the application or the "PLC Designer" / "EASY Starter".

The status signal is independent of whether or not an error has occurred.