L_IE1P_ErrorHandler
General information about the ErrorHandler
The ErrorHandler describes the component to be affected by the set error.
|
Example An error is set that is to trigger Fault_QSP as a reaction (severity). Fault_QSP is a reaction, which stops an inverter by default. Thus the components axes or groups of axes can be connected to an input ErrorHandler, because these then derive a reaction automatically. |
|
|
|
|
L_IE1P_ErrorHandler |
|
|
|
|
|---|---|---|---|---|---|---|---|
|
L_IE1P_IErrorHandler |
– |
AddErrorHandler1 |
|||||
|
L_IE1P_IErrorHandler |
– |
AddErrorHandler2 |
|||||
|
L_IE1P_IErrorHandler |
– |
AddErrorHandler3 |
|||||
|
L_IE1P_IErrorHandler |
– |
AddErrorHandler4 |
|||||
|
|
|
|
|
|
|
|
|
|
Name Datentyp |
Information/possible settings |
|
|---|---|---|
|
AddErrorHandler[1 ... 4] L_IE1P_IErrorHandler |
Optional connection of the function block instance of a component in which the error reaction is to be executed. The following types can be currently connected:
|
|
Example:
The axes Axis21_1, Axis20_1, Axis30_1 and Axis30_2 are to be set to a FAULT_QSP (20) state by a SetError module.
For this purpose, all four axes are added to a "collective-ErrorHandler":
ErrorHandler_Axes_total(
-
AddErrorHandler1:=Axis21_1 ,
-
AddErrorHandler2:=Axis20_1 ,
-
AddErrorHandler3:=Axis30_1,
-
AddErrorHandler4:=Axis30_2 );
Now only the ErrorHandler_Axes_total has to be connected to the SetError-FB.
L_IE1P_SeverityLevel