L_IE1P_ReadActualSeverity

The FB L_IE1P_ReadActualSeverity can be used to determine the error status (highest priority severity and reaction) of a module and its directly subordinate modules.

Based on the returned status (severity/reaction), it can be decided in the parent module whether a further reaction for the status machine or via FB L_IE1P_SetError must be derived from it.

See also chapter Automatic Forwarding Mechanisms for Errors

Controlled/subordinate modules include all components that have been registered directly as a child (via SetParent) to the module. Only the next level is taken into account.

 

 

 

L_IE1P_ReadActualSeverity

 

 

 

BOOL

–

 

xEnable

xBusy

 

–

BOOL

L_IMHP_IModuleHandler

–

 

ModuleHandler

xError

 

–

BOOL

BOOL

–

 

xDisableSubModules

eErrorID

 

–

L_IE1P_Error

       

eSeverity

 

–

L_IE1P_SeverityLevel

       

eReaction

 

–

L_IE1P_Reaction

       

sAffectedModuleName

 

–

String

       

AffectedModuleHandler

 

–

L_IMHP_IModuleHandler

       

xErrorActive

 

–

BOOL

       

xWarningActive

 

–

BOOL

       

SeverityStatus

 

–

L_IE1P_SeverityStatus

       

ReactionStatus

 

–

L_IE1P_ReactionStatus

 

 

 

 

 

 

 

 

Inputs

Name

Datatype

Info/ setting options

xEnable

BOOL

TRUE

Activate readout of error information

Modulehandler

L_IMHP_IModuleHandler

Definition of the affiliation of error messages to a module.

When this input is connected, the errors generated for the module are displayed at the outputs.

If the ModuleHandler input is not connected, the errors of the "Application" component are acknowledged.

The "Application" component contains error messages that were sent with an FB L_IE1P_SetError or L_IE1P_SetErrorSingle without a ModuleHandler connected.

xDisableSubmodules

BOOL

TRUE

Errors of subordinate machine modules with the component type MachineModule or GeneralMachineModule are not taken into account.

Outputs

Name

Datatype

Value/ Description

xBusy

BOOL

TRUE

The FB is processed

xError

BOOL

TRUE

An error occurred during the processing of the FB. Details see eErrorID .

eErrorID

L_IE1P_Error

If xError = TRUE: Error number for the error that occurred within the FB.

eSeverity

L_IE1P_Severity

Severity of the current error

eReaction

L_IE1P_Reaction

Commissioned reaction of the current error

Note:

The reaction that was requested with FB L_IE1P_SetErrprSingle at input eRection is displayed 1:1. The resulting reaction from the severity level is not taken into account.

sAffectedModuleName

STRING

Name of the module in which the highest priority error occurred.

AffectedModuleHandler

L_IMHP_IModuleHandler

ModuleHandler of the module in which the highest priority error occurred.

xErrorActive

BOOL

TRUE

The reported event is an error (collection bit for the severity reported at the eSeverity output).

xWarningActive

BOOL

TRUE

The reported event is a warning (collection bit for the severity reported at the eSeverity output).

SeverityStatus

L_IE1P_SeverityStatus

Collective message of all currently active severities

of the module connected via the ModuleHandler input (incl. the directly subordinate modules)

ReactionStatus

L_IE1P_ReactionStatus

Collective message of all currently active reactions

of the module connected via the ModuleHandler input (incl. the directly subordinate modules)

Query the status of a single module)

In order to obtain status information from children connected to a module.

The FB L_IE1P_ReadActualSeverity provides a method to assign the numbers of the child modules to the actual modules. Before using the method, the FB must already have been called in this application cycle.

 

 

 

ReadChildSeverity

 

 

 

WORD

–

 

wChild

ReadChildSeverity

 

–

BOOL

       

eSeverity

 

–

L_IE1P_SeverityLevel

       

eReaction

 

–

L_IE1P_Reaction

       

sChildName

 

–

String

       

ChildModuleHandler

 

–

L_IMHP_IModuleHandler

 

 

 

 

 

 

 

 

ReadActualSeverity-Konfiguration 1
  • ModuleHandler = MM_Winding

  • xDisableSubModules = FALSE

The Severites of the following modules are evaluated

MM_Winding

TM 20.1

  • There is an automatism for Lenze FBs that errors from AxisRef 20.1 and Inverter 20.1 are automatically forwarded to the TM 20.1.

MM_InfeedWinding

  • Only events that were triggered with SetErrorMM_InfeedWinding.

  • Events from TM30.1, TM30.2 are not automatically forwarded, only if they were sent via SetErrorMM_InfeedWinding for the MM_InfeedWinding.

MM_OutfeedWinding

  • Only events that were triggered with SetErrorMM_OutfeedWinding.

  • Events from TM31.1, TM31.2 are not automatically forwarded, only if they were sent via SetErrorMM_OutfeedWinding for the MM_OutfeedWinding.

ReadActualSeverity-Konfiguration 2
  • ModuleHandler = MM_Winding

  • xDisableSubModules = TRUE

The Severites of the following modules are evaluated

MM_Winding

TM 20.1

  • There is an automatism for Lenze FBs that errors from AxisRef 20.1 and Inverter 20.1 are automatically forwarded to the TM 20.1.