EtherCAT device configuration with »PLC Designer«
How to integrate the EtherCAT IO device in the control configuration:
1.
Select the "Add device" command in the context menu of the target system (device, Lenze controller, etc.) to extend the control configuration with the IO device.
The EtherCAT device is located in the category under /Fieldbusses/EtherCAT/Slave/EtherCAT-Device
The EtherCAT device is located in the category under /Fieldbusses/EtherCAT/Slave/EtherCAT-Device
2.
Name the inserted IO device sensibly.
You can enter a name by clicking on the element. The designations must only contain the characters "A ... Z", "a ... z", "0 ... 9", or "_" and must not begin with a digit.
You can enter a name by clicking on the element. The designations must only contain the characters "A ... Z", "a ... z", "0 ... 9", or "_" and must not begin with a digit.
3.
Go to the context menu of the EtherCAT device and execute the "Add device" command.
4.
In the dialog box that appears, select the I/O modules to be used for the EtherCAT device and add them to the EtherCAT device by clicking the "Add device" button. The structure of the process image is defined via the modules.
5.
In the tab for the module, define the variables for the IO signals.
The control configuration of the EtherCAT device in the »PLC Designer« is completed.
Continue with the configuration of the EtherCAT slave with TwinCAT 3.x
Continue with the configuration of the EtherCAT slave with TwinCAT 3.x
®
(see next chapter).