Acknowledgement inputs
|
Function included in variant:
|
|
|
Extended Safety - ST
|
Error acknowledgement (AIE)
Errors require acknowledgement with the AIE signal.
Error acknowledgement via the safe input AIE:
–
Positive signal pulse from 0.3 ... 10 s.
–
Acknowledgement with the negative edge.
Restart acknowledgement (AIS)
After a stop function has been executed, the restart requires an acknowledgement with the AIS signal if "acknowledged restart" is set:
Restart acknowledgement via the safe input AIS:
–
Positive signal pulse from 0.3 ... 10 s.
–
Acknowledgement with the negative edge.
Acknowledgement signals