0x3A-Safety Validator Object

The "Safety Validator Object" generates safe I/O data packets from the application data and receives safe I/O data packets.
 
Class attributes
Attribute ID
Service
Name
Data type
Information
1
Get
Revision
UINT
Revision of the Safety Validator Object Class Definition: 1
8
Get
Safety Connection Fault Count
UINT
Diagnostic counter (for a continuous count of safety connection errors)
 
Instance attributes (instance ID 1 and 2)
Attribute ID
Service
Name
Data type
Information
1
Get
Safety Validator State
USINT
Status of the safe connection:
0: Unallocated
1 Initializing
2: Established
3: Connection_Failed
4 ... 255: Reserved
2
Get
Safety Validator Type
USINT
Safety Validator Type used in this instance:
0: Unallocated
1 Singlecast
2: Multicast
3 ... 255: Reserved
3
Get
Ping Interval EPI Multiplier
UINT
Number that defines the "Ping_Count_Interval" for a specific connection.
4
Get
Time Coord Msg Min Multiplier
Struct of:
Time Coord Msg Min Multiplier Array Size
USINT
Array size:
= [Max Consumer Number] for Multicast Producer
= 1 for Singlecast and Multicast Consumer
Time Coord Msg Min Multiplier
Array of UINT
Minimum number of 128-
µ
s steps that a Time Coordination Message could require for the path from the consumer to the producer.
–
Value range: 0 ... 7813
 
5
Get
Network Time Expectation Multiplier
Struct of:
Network Time Expectation Multiplier Array Size
USINT
Array size:
= [Max Consumer Number] for Multicast Producer
= 1 for Singlecast and Multicast Consumer
Network Time Expectation Multiplier
Array of UINT
Minimum number of 128-
µ
s steps that a consumer should allow the age of the safety data to reach.
–
Value range: 0 ... 45313
 
6
Get
Timeout Multiplier
Struct of:
Timeout Multiplier Array Size
USINT
Array size:
= [Max Consumer Number] for Multicast Producer
= 1 for Singlecast and Multicast Consumer
Timeout Multiplier
Array of USINT
Number of messages that may be lost before a connection error is detected.
–
Basic Format: 1 ... 4
 
–
Extended Format: 1 ... 255
 
7
Get
Max Consumer Number
USINT
Maximum number of consumers allowed for the connection.
–
1 (for singlecast)
 
–
2 ... 15 (für multicast)
 
12
Get/Set
Max Data Age
UINT
This attribute is only updated by Safety Consumers and contains the largest determined data age for a diagnosis in 128-
µ
s increments.
–
"Set" service is only supported for consumers.
 
–
The only valid set value is "0".
 
13
Get
Application Data Path
Packed EPATH
Refers to the application data in relation to the security association.
14
Get
Error Code
UINT
Error code within this instance:
0: no error, otherwise implementation-specific error code.
15
Get
Producer/Consumer Fault Counters
Struct of:
Producer/Consumer Fault Counter Array Size
USINT
Array size:
= [Max Consumer Number] for Multicast Producer
= 1 for Singlecast and Multicast Consumer
Producer/Consumer Fault Counter
Array of USINT
Number of errors detected in this hour.
 
Supported service codes
Service code
Name
Information
0x0E
Get_Attribute_Single
Outputs the value of a specific attribute.
0x10
Set_Attribute_Single
Changes the value of a specific attribute.
0x4B
Reset_all_error_counters
Resets the class attribute 8 (Safety Connection Fault Count) in all instances.
 
Related topics