Output data/assemblies are created by the PLC (Scanner) and transmitted to the inverter (Adapter).
–
Input data/assemblies are created by the inverter (Adapter) and transmitted to the PLC (Scanner).
|
|
Process data transfer (Implicit Messaging)
Parameter data transfer (Explicit Messaging)|
Attribute ID
|
Name
|
Info / parameter
|
|
Assembly output object instances according to AC-Drive profile
|
||
|
20
|
Basic Speed Control Output
|
Bit 0 and 2 of the LSB of the AC drive control word 0x400B:001
0x400B:004 Network setpoint speed |
|
21
|
Extended Speed Control Output
|
LSB of the AC drive control word 0x400B:001
0x400B:004 Network setpoint speed |
|
22
|
Speed and Torque Control Output
|
Bit 0 and 2 of the LSB of the AC drive control word 0x400B:001
0x400B:004 Network setpoint speed 0x400B:008 Torque mode setpoint |
|
23
|
Extended Speed and Torque Control Output
|
LSB of the AC drive control word 0x400B:001
0x400B:004 Network setpoint speed 0x400B:008 Torque mode setpoint |
|
Assembly input object instances according to AC drive profile
|
||
|
70
|
Basic Speed Control Input
|
Bit 0 and 2 of the LSB of the AC drive status word 0x400C:001
0x400C:004 Motor speed |
|
71
|
Extended Speed Control Input
|
LSB from AC drive status word 0x400C:001
MSB Drive State of the AC drive status word (mask bits 12 ... 15)
0x400C:004 Motor speed |
|
72
|
Speed and Torque Control Input
|
Bit 0 and 2 of the LSB of the AC drive status word 0x400C:001
0x400C:004 Motor speed 0x400C:007 Torque scaled |
|
73
|
Extended Speed and Torque Control Input
|
LSB from AC drive status word 0x400C:001
MSB Drive State of the AC drive status word (mask bits 12 ... 15)
0x400C:004 Motor speed 0x400C:007 Torque scaled |
|
Assembly object instances for customer-specific configurations
|
||
|
110
|
Custom Output
|
Control data sent to the inverter
Data size: mapped data + 4 byte header
–
Depending on your controller, you may need to add the 4-byte header manually.
|
|
111
|
Custom Input
|
Status data sent by the inverter
Data size: mapped data + 4 byte header
–
Depending on your controller, you may need to add the 4-byte header manually.
|
|
130
|
Configuration
|
Data for configuring the assembly object instances 110 and 111
Data size:
–
68 bytes when used with 110 and 111
–
0 bytes for all other assembly object instances
|
|
Assembly object instances according to CIP Safety profile (only for inverters with "Extended Safety")
|
||
|
161
|
Safety Output with STO
|
CIP Safety output data
|
|
171
|
Safety Input with STO
|
CIP Safety input data
|
|
Attribute ID
|
Service
|
Name
|
Data type
|
Value
|
|
3
|
Get/Set
|
Data
|
Array of octet
|
Instance/class-specific
|
|
4
|
Get
|
Size
|
UINT
|
Number of bytes in attribute 3 (Data), instance/class-specific
|
|
Service code
|
Name
|
Information
|
|
0x0E
|
Get_Attribute_Single
|
Outputs the value of a specific attribute.
|
|
0x10
|
Set_Attribute_Single
|
Changes the value of a specific attribute.
|
|
Attribute
(Instance ID)
|
Byte
|
Bit 7
|
Bit 6
|
Bit 5
|
Bit 4
|
Bit 3
|
Bit 2
|
Bit 1
|
Bit 0
|
|
20
(0x14)
|
0
|
|
|
|
|
|
FaultRst
|
|
RunFwd (CW)
|
|
1
|
|
||||||||
|
2
|
Speed Reference (low byte)
|
||||||||
|
3
|
Speed Reference (high byte)
|
||||||||
|
21
(0x15)
|
0
|
|
NetRef
|
NetCtrl
|
|
|
FaultRst
|
RunRev (CCW)
|
RunFwd (CW)
|
|
1
|
|
||||||||
|
2
|
Speed Reference (low byte)
|
||||||||
|
3
|
Speed Reference (high byte)
|
||||||||
|
22
(0x16)
|
0
|
|
|
|
|
|
FaultRst
|
|
RunFwd (CW)
|
|
1
|
|
||||||||
|
2
|
Speed Reference (low byte)
|
||||||||
|
3
|
Speed Reference (high byte)
|
||||||||
|
4
|
Torque Reference (low byte)
|
||||||||
|
5
|
Torque Reference (high byte)
|
||||||||
|
23
(0x17)
|
0
|
|
NetRef
|
NetCtrl
|
|
|
FaultRst
|
RunRev (CCW)
|
RunFwd (CW)
|
|
1
|
|
||||||||
|
2
|
Speed Reference (low byte)
|
||||||||
|
3
|
Speed Reference (high byte)
|
||||||||
|
4
|
Torque Reference (low byte)
|
||||||||
|
5
|
Torque Reference (high byte)
|
||||||||
|
110
(0x6E)
|
0
...
31
|
Custom Output
|
|||||||
|
Attribute
(Instance ID)
|
Byte
|
Bit 7
|
Bit 6
|
Bit 5
|
Bit 4
|
Bit 3
|
Bit 2
|
Bit 1
|
Bit 0
|
|
70
(0x46)
|
0
|
|
|
|
|
|
Running1
(Fwd, CW)
|
|
Faulted
|
|
1
|
|
||||||||
|
2
|
Speed Actual (low byte)
|
||||||||
|
3
|
Speed Actual (high byte)
|
||||||||
|
71
(0x47)
|
0
|
AtReference
|
RefFromNet
|
CtrlFromNet
|
Ready
|
Running2
(Rev, CCW)
|
Running1
(Fwd, CW)
|
Warning
|
Faulted
|
|
1
|
Drive State
|
||||||||
|
2
|
Speed Actual (low byte)
|
||||||||
|
3
|
Speed Actual (high byte)
|
||||||||
|
72
(0x48)
|
0
|
|
|
|
|
|
Running1
(Fwd, CW)
|
|
Faulted
|
|
1
|
|
||||||||
|
2
|
Speed Actual (low byte)
|
||||||||
|
3
|
Speed Actual (high byte)
|
||||||||
|
4
|
Torque Actual (low byte)
|
||||||||
|
5
|
Torque Actual (high byte)
|
||||||||
|
73
(0x49)
|
0
|
AtReference
|
RefFromNet
|
CtrlFromNet
|
Ready
|
Running2
(Rev, CCW)
|
Running1
(Fwd, CW)
|
Warning
|
Faulted
|
|
1
|
Drive State
|
||||||||
|
2
|
Speed Actual (low byte)
|
||||||||
|
3
|
Speed Actual (high byte)
|
||||||||
|
4
|
Torque Actual (low byte)
|
||||||||
|
5
|
Torque Actual (high byte)
|
||||||||
|
111
(0x6F)
|
0
...
31
|
Custom Input
|
|||||||
|
Name
|
Value
|
Size [byte]
|
|
Input 1
|
Input parameter
|
2
|
|
Input 2
|
Input parameter
|
2
|
|
Input 3
|
Input parameter
|
2
|
|
Input 4
|
Input parameter
|
2
|
|
Input 5
|
Input parameter
|
2
|
|
Input 6
|
Input parameter
|
2
|
|
Input 7
|
Input parameter
|
2
|
|
Input 8
|
Input parameter
|
2
|
|
Input 9
|
Input parameter
|
2
|
|
Input 10
|
Input parameter
|
2
|
|
Input 11
|
Input parameter
|
2
|
|
Input 12
|
Input parameter
|
2
|
|
Input 13
|
Input parameter
|
2
|
|
Input 14
|
Input parameter
|
2
|
|
Input 15
|
Input parameter
|
2
|
|
Input 16
|
Input parameter
|
2
|
|
Input Trailing Data
|
100
|
2
|
|
Output 1
|
Output parameter
|
2
|
|
Output 2
|
Output parameter
|
2
|
|
Output 3
|
Output parameter
|
2
|
|
Output 4
|
Output parameter
|
2
|
|
Output 5
|
Output parameter
|
2
|
|
Output 6
|
Output parameter
|
2
|
|
Output 7
|
Output parameter
|
2
|
|
Output 8
|
Output parameter
|
2
|
|
Output 9
|
Output parameter
|
2
|
|
Output 10
|
Output parameter
|
2
|
|
Output 11
|
Output parameter
|
2
|
|
Output 12
|
Output parameter
|
2
|
|
Output 13
|
Output parameter
|
2
|
|
Output 14
|
Output parameter
|
2
|
|
Output 15
|
Output parameter
|
2
|
|
Output 16
|
Output parameter
|
2
|
|
Output Trailing Data
|
101
|
2
|
|
Selection for "Input parameter"
|
|
Selection for "Output parameter"
|
||||
|
Value
|
Name
|
Size [byte]
|
Value
|
Name
|
Size [byte]
|
|
|
0
|
ignore
|
N/A
|
|
0
|
ignore
|
N/A
|
|
1
|
Generic SINT Input *
|
1
|
|
51
|
Generic SINT Output *
|
1
|
|
2
|
Generic INT Input *
|
2
|
|
52
|
Generic INT Output *
|
2
|
|
3
|
Generic DINT Input *
|
4
|
|
53
|
Generic DINT Output *
|
4
|
|
4
|
2B0B/0 Freq Setpoint Hz
|
2
|
|
54
|
2946/1 Trq Mode Hi Spd
|
4
|
|
5
|
2D40/4 Device Load Act.
|
2
|
|
55
|
2946/2 Trq Mode Lo Spd
|
4
|
|
6
|
2D4F/0 Motor i2t utiliz.
|
2
|
|
56
|
4008/1 NetWordIN1
|
2
|
|
7
|
2D82/0 Motor voltage
|
4
|
|
57
|
4008/2 NetWordIN2
|
2
|
|
8
|
2D88/0 Motor current
|
2
|
|
58
|
reserved/ignore
|
2
|
|
9
|
2DA2/1 Effective Power
|
4
|
|
59
|
reserved/ignore
|
2
|
|
10
|
2DA2/2 Apparent Power
|
4
|
|
60
|
400B/1 AC Drv Ctrl Word
|
2
|
|
11
|
2DA3/1 Energy Out Motor
|
4
|
|
61
|
reserved/ignore
|
2
|
|
12
|
2DA3/2 Energy Out Gen.
|
4
|
|
62
|
400B/3 Net Spd Stpnt Hz
|
2
|
|
13
|
reserved/ignore
|
2
|
|
63
|
400B/4 Net Spd Stpnt RPM
|
2
|
|
14
|
2
|
|
64
|
400B/5 Net Spd 0.01 Hz
|
2
|
|
|
15
|
2
|
|
65
|
400B/6 NetSpdSign 0.1Hz
|
2
|
|
|
16
|
2
|
|
66
|
400B/7 Net PID Stpnt
|
2
|
|
|
17
|
2
|
|
67
|
400B/8 Net Torque Stpnt
|
2
|
|
|
18
|
2
|
|
68
|
6040/0 Control Word
|
2
|
|
|
19
|
2
|
|
69
|
6042/0 Target Velocity
|
2
|
|
|
20
|
2
|
|
70
|
6046/1 Velocity Min
|
4
|
|
|
21
|
2
|
|
71
|
6046/2 Velocity Max
|
4
|
|
|
22
|
2
|
|
72
|
6048/1 Delta Speed
|
4
|
|
|
23
|
2
|
|
73
|
6048/2 Delta Time
|
2
|
|
|
24
|
2DD3/1 Speed set
|
4
|
|
74
|
6049/1 Delta Speed
|
4
|
|
25
|
reserved/ignore
|
2
|
|
75
|
6049/2 Delta Time
|
2
|
|
26
|
2DDD/0 Actual Frequency
|
2
|
|
76
|
6060/0 402 Control Modes
|
1
|
|
27
|
400A/1 NetWordOUT1
|
2
|
|
77
|
6071/0 402 Target Torque
|
2
|
|
28
|
reserved/ignore
|
2
|
|
78
|
6080/0 Motor Max Speed
|
4
|
|
29
|
400C/1 AC Drv Stat Word
|
2
|
|
79
|
60E0/0 Pos Torque Limit
|
2
|
|
30
|
reserved/ignore
|
2
|
|
80
|
60E1/0 Neg Torque Limit
|
2
|
|
31
|
400C/3 Actual Speed Hz
|
2
|
|
81
|
reserved/ignore
|
1
|
|
32
|
400C/4 Actual Speed RPM
|
2
|
|
82
|
400B/13 Process Input Freq.
|
2
|
|
33
|
400C/5 Drive State
|
2
|
|
83
|
reserved/ignore
|
-
|
|
34
|
400C/6 Act Speed 0.01Hz
|
2
|
|
...
|
-
|
|
|
35
|
400C/7 Actual Torque Scaled
|
2
|
|
101
|
-
|
|
|
36
|
reserved/ignore
|
2
|
|
|
|
|
|
37
|
401F/1 Actual PID Stpnt
|
2
|
|
* Selection can be used to specify only the data size of the parameters in the PLC (Scanner). The desired parameters with the corresponding data size can then be assigned manually for the inverter (Adapter) in the »EASY Starter«:
"Settings" tab à Overview à Fieldbus EtherNet/IP à Mapping fieldbus dataData format of the parameters:
Parameter attribute list |
||
|
38
|
401F/2 Actual PID Fbk
|
2
|
|
|||
|
39
|
401F/3 PID bits
|
1
|
|
|||
|
40
|
603F/0 Current Fault
|
2
|
|
|||
|
41
|
6041/0 Status Word
|
2
|
|
|||
|
42
|
6043/0 Velocity Demand
|
2
|
|
|||
|
43
|
6044/0 Velocity Actual
|
2
|
|
|||
|
44
|
6061/0 402 Mode Display
|
1
|
|
|||
|
45
|
6077/0 402 ActualTorq %
|
2
|
|
|||
|
46
|
6078/0 402 ActualCur %
|
2
|
|
|||
|
47
|
6079/0 402 DClink Volt
|
4
|
|
|||
|
48
|
60FD/0 Dig Inputs Stat
|
4
|
|
|||
|
49
|
reserved/ignore
|
-
|
|
|||
|
50
|
400C/9 Process Output Freq.
|
2
|
|
|||