0x29-Control Supervisor Object
The "Control Supervisor Object" describes all management functions of the device for the motor control.
|
Attribute ID
|
Name
|
Info / parameter
|
|
3
|
Run1
|
AC drive control word 0x400B:001: Bit 0 (run forward, CW)
|
|
4
|
Run2
|
AC drive control word 0x400B:001: Bit 1 (run reverse, CCW)
|
|
5
|
NetCtrl
|
AC Drive control word 0x400B:001: Bit 5 (activate network control: 0x2631:037 = 114)
|
|
6
|
State
|
AC drive status word 0x400C:001:
Bits 8 ... 11 (profile status/Drive State)
Bits 12 ... 15 masked
|
|
7
|
Running1
|
AC drive status word 0x400C:001: Bit 2 (run forward active, CW)
|
|
8
|
Running2
|
AC drive status word 0x400C:001: Bit 3 (run reverse active, CCW)
|
|
9
|
Ready
|
AC drive status word 0x400C:001: Bit 4 (ready)
|
|
10
|
Faulted
|
AC drive status word 0x400C:001: Bit 0 (fault/trouble active)
|
|
11
|
Warning
|
AC drive status word 0x400C:001: Bit 1 (warning active)
|
|
12
|
FaultRst
|
AC drive control word 0x400B:001: Bit 2 (error reset)
|
|
13
|
FaultCode
|
Error code 0x603F
|
|
15
|
CtrlFromNet
|
AC drive status word 0x400C:001: Bit 5 (network control active)
|
|
CiA 402 plus States
|
AC Drive Profile Drive States
|
|
START (0)
|
0: Manufacturer-specific
|
|
NOT_READY_TO_SWITCH_ON (2)
|
1: Startup (drive initialization)
|
|
SWITCH_ON_DISABLED (3)
|
2: Not_Ready (mains voltage switched off)
|
|
READY_TO_SWITCH_ON (4)
|
3: Ready (mains voltage switched on)
|
|
SWITCHED_ON (5)
|
|
|
OPERATION_ENABLED (6)
|
4: Enabled (drive has received run command)
|
|
DISABLE_OPERATION (7)
|
5: Stopping (drive has received stop command and is stopped)
|
|
SHUT_DOWN (8)
|
|
|
QUICK_STOP (9)
|
|
|
FAULT_REACTION_ACTIVE (10)
|
6: Fault_Stop (drive is stopped due to a fault)
|
|
FAULT (11)
|
7: Faulted (faults have occurred)
|