Homing modes
|
Designation
|
|
Evaluated signals/sensors
|
|||
|
TP sensor
Encoder zero pulse
|
Travel range limit switch
|
Reference switch
|
|||
|
negative
|
positive
|
||||
|
CwTorqueLimit
|
-2
|
Positive direction to torque limit
|
|||
|
CcwTorqueLimit
|
-1
|
Negative direction to torque limit
|
|||
|
CcwLimitSwitchCwTP
|
1
|
X
|
X
|
|
|
|
SetPositionDirect
|
0
|
Set reference directly
|
|||
|
CwLimitSwitchCcwTP
|
2
|
X
|
|
X
|
|
|
CwRpCcwRnTP
|
3
|
X
|
|
|
X
|
|
CcwRpCwRnTP
|
5
|
X
|
|
|
X
|
|
CcwLimitSwitch
|
17
|
|
X
|
|
|
|
CwLimitSwitch
|
18
|
|
|
X
|
|
|
CwRpCcwRn
|
19
|
X
|
|
|
X
|
|
CcwRpCwRn
|
21
|
X
|
|
|
X
|
|
CcwTP
|
33
|
X
|
|
|
|
|
CwTP
|
34
|
X
|
|
|
|
|
ResetHomeInfo
|
99
|
Reset of status "Reference known"
|
|||
Homing mode 1: CcwLimitSwitchCwTP
Fig. 1: Negative direction with reversing limit switch to touch probe
A
Touch probe/zero pulse
B
Negative travel range limit switch
Sequence of case
①
:1.
The machine part moves in negative direction with profile data set 1.
2.
The machine part reverses to the negative travel range limit switch (B) and changes to profile data set 2.
3.
The negative edge of the travel range limit switch (B) activates the touch probe detection.
4.
The following positive edge of the encoder zero pulse/touch probe sensor (A) sets the reference.
5.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Homing mode 2: CwLimitSwitchCcwTP
Fig. 2: Positive direction with reversing limit switch to touch probe
A
Touch probe/zero pulse
B
Positive travel range limit switch
Sequence of case
①
:1.
The machine part moves in positive direction with profile data set 1.
2.
Machine part reverses to positive travel range switch (B) and changes to profile data set 2.
3.
The negative edge of the travel range limit switch (B) activates the touch probe detection.
4.
The following positive edge of the encoder zero pulse/touch probe sensor (A) sets the reference.
5.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Reference run 3: CwRpCcwRnTP
Fig. 3: Positive direction with reversing limit switch and negative edge of the reference switch to touch probe
A
Touch probe/zero pulse
B
Reference switch
Sequence of case
①
:The axis has not yet activated the reference switch:
1.
The machine part moves in positive direction with profile data set 1.
2.
The machine part reverses with positive edge of the reference switch (B) and changes to profile data set 2.
3.
The negative edge of the reference switch (B) activates the touch probe detection.
4.
The following positive edge of the encoder zero pulse/touch probe sensor (A) sets the reference.
5.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning around a set target position.
–
Absolute positioning to a set target position.
Sequence for case
②
:The axis has already activated the reference switch:
1.
The machine part moves in negative direction with profile data set 2.
2.
The negative edge of the reference switch (B) activates the touch probe detection.
3.
The following positive edge of the encoder zero pulse/touch probe sensor (A) sets the reference.
4.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning around a set target position.
–
Absolute positioning to a set target position.
Homing mode 5: CcwRpCwRnTP
Fig. 4: Negative direction with reversing reference switch and negative edge of the reference switch to touch probe
A
Touch probe/zero pulse
B
Reference switch
Sequence of case
①
:The axis has not yet activated the reference switch:
1.
The machine part moves in negative direction with profile data set 1.
2.
The machine part reverses with positive edge of the reference switch (B) and changes to profile data set 2.
3.
The negative edge of the reference switch (B) activates the touch probe detection.
4.
The following positive edge of the encoder zero pulse/touch probe sensor (A) sets the reference.
5.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Sequence of case
②
:The axis has already activated the reference switch:
1.
The machine part moves in positive direction with profile data set 2.
2.
The negative edge of the reference switch (B) activates the touch probe detection.
3.
The following positive edge of the encoder zero pulse/touch probe sensor (A) sets the reference.
4.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Homing mode 17: CcwLimitSwitch
Fig. 5: Negative direction to limit switch
A
Negative travel range limit switch
Sequence of case
①
:1.
The machine part moves in negative direction with profile data set 1.
2.
The machine part reverses to negative travel range limit switch (A) and changes to profile data set 2.
3.
The following negative edge of the travel range limit switch (A) sets the reference.
4.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Homing mode 18: CwLimitSwitch
Fig. 6: Positive direction to limit switch
A
Positive travel range limit switch
Sequence of case
①
:1.
The machine part moves in positive direction with profile data set 1.
2.
The machine part reverses to positive travel range limit switch (A) and changes to profile data set 2.
3.
The following negative edge of the travel range limit switch (A) sets the reference.
4.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Homing mode 19: CwRpCcwRn
Fig. 7: Sequence representation of case 1 and case 2
A
Reference switch
Sequence of case
①
:The axis has not yet activated the reference switch:
1.
The machine part moves in positive direction with profile data set 1.
2.
Machine part reverses with positive edge of the reference switch (A) and changes to profile data set 2.
3.
The negative edge of the reference switch (A) sets the reference.
4.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Sequence of case
②
:The axis has already activated the reference switch:
1.
The machine part moves in negative direction with profile data set 2.
2.
The negative edge of the reference switch (A) sets the reference.
3.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Homing mode 21: CcwRpCwRn
Fig. 8: Sequence representation of case 1 and case 2
A
Reference switch
Sequence of case
①
:The axis has not yet activated the reference switch:
1.
The machine part moves in negative direction with profile data set 1.
2.
The machine part reverses with positive edge of the reference switch (A) and changes to profile data set 2.
3.
The negative edge of the reference switch (A) sets the reference.
4.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Sequence of case
②
:The axis has already activated the reference switch:
1.
The machine part moves in positive direction with profile data set 2.
2.
The negative edge of the reference switch (A) sets the reference.
3.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Homing mode 33: CcwTP
Fig. 9: Negative direction to touch probe
A
Touch probe/zero pulse
Sequence of case
①
:1.
The machine part moves to negative direction with profile data set 1 and activates the touch probe detection.
2.
The following set edge of the encoder zero pulse/touch probe sensor (A) sets the reference.
3.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Homing mode 34: CwTP
Fig. 10: Positive direction to touch probe
A
Touch probe/zero pulse
Sequence of case
①
:1.
The machine part moves to positive direction with profile data set 1 and activates the touch probe detection.
2.
The following set edge of the encoder zero pulse/touch probe sensor (A) sets the reference.
3.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Homing mode -1: CcwTorqueLimit
Fig. 11: Negative direction to torque limit
Sequence of case
①
:1.
The machine part moves in negative direction with reduced torque and profile data set 1.
2.
The reference is set if the following two conditions for the set blocking time are fulfilled at the same time:
–
The current speed is lower than the threshold set for standstill detection.
–
The current torque is higher than the set torque limit (homing to end stop).
3.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.
Homing mode -2: CwTorqueLimit
Fig. 12: Positive direction to torque limit
Sequence of case
①
:1.
The machine part moves in positive direction with reduced torque and profile data set 1.
2.
The reference is set if the following two conditions for the set blocking time are fulfilled at the same time:
–
The current speed is lower than the threshold set for standstill detection.
–
The current torque is higher than the set torque limit (homing to end stop).
3.
Further actions can be selected:
–
Drive stops (default setting).
–
Relative positioning by a set target position.
–
Absolute positioning to a set target position.