Homing process
How to perform homing:
1.
Parameterize homing.
2.
Select CiA operating mode for homing.
0x6060 (CiA: Operation mode) = [6] CiA: Homing
0x6060 (CiA: Operation mode) = [6] CiA: Homing3.
Check whether the CiA operating mode is active.
0x6061 (CiA: Active operation mode) = [6] CiA: Homing
0x6061 (CiA: Active operation mode) = [6] CiA: Homing4.
Enable inverter.
Enable operation
Enable operation 5.
Start homing.
0x6040 (CiA control word) Bit 4 = 1
0x6040 (CiA control word) Bit 4 = 16.
Wait until homing is completed.
0x6041 (CiA status word) Bit 12 = 1 (homing completed)
0x6041 (CiA status word) Bit 12 = 1 (homing completed)7.
Check if homing was error-free.
0x6041 (CiA status word) Bit 13 = 1 (no error detected during homing)
0x6041 (CiA status word) Bit 13 = 1 (no error detected during homing)8.
Disable inverter.
0x6040 (CiA control word) Bit 3 = 0
0x6040 (CiA control word) Bit 3 = 0Homing is completed.
The operating mode for normal operation can be selected, e.g.
0x6060 (CiA: Operation mode) = [8] CiA: Cyclic sync position (csp)
The operating mode for normal operation can be selected, e.g.
0x6060 (CiA: Operation mode) = [8] CiA: Cyclic sync position (csp)Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x503F:071
|
Action after "Home position detected"
|
Action of the drive after the home position has been detected.
|
|
|
0
|
Stop positioning
|
The drive stops.
|
|
|
1
|
Relative positioning
|
Relative positioning by the distance set in 0x503F:072.
|
|
|
2
|
Absolute positioning
|
Absolute positioning to the position set in 0x503F:072
|
|
|
0x503F:072
|
Homing: Target position
-2147483648.0000000000 ... [0.0000000000] ... 2147483647.0000000000 incr.
|
–
Distance if 0x503F:071 = [1] (Relative positioning)
–
Absolute position if 0x503F:071 = [2] (Absolute positioning)
|
|
|
0x503F:077
|
Homing: Jerk
0.0000000000 ... [0.0000000000] ... 2147483647.0000000000
|
Jerk for homing
|
|
|
0x503F:078
|
Homing: Torque limit
0.0000 ... [0.0000] ... 214748.3647 Nm
|
||
|
0x503F:079
|
Homing: Blocking time
0.000 ... [0.000] ... 2147483.647 s
|
Only for "homing to end stop":
The reference is set when the drive is at standstill during the blocking time and the actual torque is greater than the torque limit.
|
|
|
0x503F:080
|
Homing: Touch probe configuration
|
Selection of the source for setting the home position
|
|
|
0
|
External source
|
||
|
1
|
TP1 - positive edge
|
Edge of the touch probe sensor at DI1
|
|
|
2
|
TP1 - negative edge
|
||
|
3
|
TP1 - any edge
|
||
|
4
|
TP1 - zero pulse
|
Zero pulse of the motor encoder
|
|
|
11
|
TP2 - positive edge
|
Edge of the touch probe sensor at DI2
|
|
|
12
|
TP2 - negative edge
|
||
|
13
|
TP2 - any edge
|
||
|
14
|
TP2 - zero pulse
|
Zero pulse of the motor encoder
|
|
|
21
|
TP3 - positive edge
|
Edge of the touch probe sensor at DI3
|
|
|
22
|
TP3 - negative edge
|
||
|
23
|
TP3 - any edge
|
||
|
24
|
TP3 - zero pulse
|
Zero pulse of the motor encoder
|
|
|
31
|
TP4 - positive edge
|
Edge of the touch probe sensor at DI4
|
|
|
32
|
TP4 - negative edge
|
||
|
33
|
TP4 - any edge
|
||
|
34
|
TP4 - zero pulse
|
Zero pulse of the motor encoder
|
|
|
0x607C
|
Homing: Home position offset
-2147483648.0000000000 ... [0.0000000000] ... 2147483647.0000000000 incr.
|
Absolute position set when the reference event is detected.
|
|
|
0x6098
|
Homing mode
|
||
|
-2
|
CwTorqueLimit
|
||
|
-1
|
CcwTorqueLimit
|
||
|
0
|
SetPositionDirect
|
||
|
1
|
CcwLimitSwitchCwTP
|
||
|
2
|
CwLimitSwitchCcwTP
|
||
|
3
|
CwRpCcwRnTP
|
||
|
5
|
CcwRpCwRnTP
|
||
|
17
|
CcwLimitSwitch
|
||
|
18
|
CwLimitSwitch
|
||
|
19
|
CwRpCcwRn
|
||
|
21
|
CcwRpCwRn
|
||
|
33
|
CcwTP
|
||
|
34
|
CwTP
|
||
|
99
|
Reset home position
|
||
|
0x6099:001
|
Homing: Velocity for searching switch
0.0000000000 ... [0.0000000000] ... 4294967295.0000000000
|
||
|
0x6099:002
|
Homing: Velocity for searching 0
0.0000000000 ... [0.0000000000] ... 4294967295.0000000000
|
||