Homing process

How to perform homing:
1.
Parameterize homing.
 
2.
Select CiA operating mode for homing. 0x6060 (CiA: Operation mode) = [6] CiA: Homing
 
3.
Check whether the CiA operating mode is active. 0x6061 (CiA: Active operation mode) = [6] CiA: Homing
 
4.
Enable inverter. Enable operation 
 
5.
Start homing. 0x6040 (CiA control word) Bit 4 = 1
 
6.
Wait until homing is completed. 0x6041 (CiA status word) Bit 12 = 1 (homing completed)
 
7.
Check if homing was error-free. 0x6041 (CiA status word) Bit 13 = 1 (no error detected during homing)
 
8.
Disable inverter. 0x6040 (CiA control word) Bit 3 = 0
 
Homing is completed.
The operating mode for normal operation can be selected, e.g. 0x6060 (CiA: Operation mode) = [8] CiA: Cyclic sync position (csp)
 
Parameter
Address
Name / setting range / [default setting]
Information
0x503F:071
Action after "Home position detected"
Action of the drive after the home position has been detected.
0
Stop positioning
The drive stops.
1
Relative positioning
Relative positioning by the distance set in 0x503F:072.
2
Absolute positioning
Absolute positioning to the position set in 0x503F:072
0x503F:072
Homing: Target position
-2147483648.0000000000 ... [0.0000000000] ... 2147483647.0000000000 incr.
–
Distance if 0x503F:071 = [1] (Relative positioning)
 
–
Absolute position if 0x503F:071 = [2] (Absolute positioning)
 
0x503F:077
Homing: Jerk
0.0000000000 ... [0.0000000000] ... 2147483647.0000000000
Jerk for homing
0x503F:078
Homing: Torque limit
0.0000 ... [0.0000] ... 214748.3647 Nm
0x503F:079
Homing: Blocking time
0.000 ... [0.000] ... 2147483.647 s
Only for "homing to end stop":
Homing mode
–
0x6098 = [-2] (CwTorqueLimit)
 
–
0x6098 = [-1] (CcwTorqueLimit)
 
The reference is set when the drive is at standstill during the blocking time and the actual torque is greater than the torque limit.
0x503F:080
Homing: Touch probe configuration
Selection of the source for setting the home position
0
External source
1
TP1 - positive edge
Edge of the touch probe sensor at DI1
2
TP1 - negative edge
3
TP1 - any edge
4
TP1 - zero pulse
Zero pulse of the motor encoder
11
TP2 - positive edge
Edge of the touch probe sensor at DI2
12
TP2 - negative edge
13
TP2 - any edge
14
TP2 - zero pulse
Zero pulse of the motor encoder
21
TP3 - positive edge
Edge of the touch probe sensor at DI3
22
TP3 - negative edge
23
TP3 - any edge
24
TP3 - zero pulse
Zero pulse of the motor encoder
31
TP4 - positive edge
Edge of the touch probe sensor at DI4
32
TP4 - negative edge
33
TP4 - any edge
34
TP4 - zero pulse
Zero pulse of the motor encoder
0x607C
Homing: Home position offset
-2147483648.0000000000 ... [0.0000000000] ... 2147483647.0000000000 incr.
Absolute position set when the reference event is detected.
0x6098
Homing mode
-2
CwTorqueLimit
-1
CcwTorqueLimit
0
SetPositionDirect
1
CcwLimitSwitchCwTP
2
CwLimitSwitchCcwTP
3
CwRpCcwRnTP
5
CcwRpCwRnTP
17
CcwLimitSwitch
18
CwLimitSwitch
19
CwRpCcwRn
21
CcwRpCwRn
33
CcwTP
34
CwTP
99
Reset home position
0x6099:001
Homing: Velocity for searching switch
0.0000000000 ... [0.0000000000] ... 4294967295.0000000000
0x6099:002
Homing: Velocity for searching 0
0.0000000000 ... [0.0000000000] ... 4294967295.0000000000