Information on the network
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2302:001
|
Active CANopen settings: Active node ID
–
Read only
|
Display of the active node address.
|
|
|
0x2302:002
|
Active CANopen settings: Active baud rate
–
Read only
|
Display of the active baud rate.
|
|
|
0
|
Automatic
|
||
|
1
|
20 kbps
|
||
|
2
|
50 kbps
|
||
|
3
|
125 kbps
|
||
|
4
|
250 kbps
|
||
|
5
|
500 kbps
|
||
|
6
|
800 kbps
|
||
|
7
|
1 Mbps
|
||
|
0x2307
|
CANopen time-out status
–
Read only
|
Bit-coded status display of the CAN time monitoring functions.
|
|
|
Bit
0
|
RPDO1-Timeout
|
1 = RPDO1 was not received within the monitoring time or not with the sync configured.
–
Status is reset automatically after the RPDO has been received again.
–
Setting of monitoring time for RPDO1 in 0x2304:045.
|
|
|
Bit
1
|
RPDO2-Timeout
|
1 = RPDO2 was not received within the monitoring time or not with the sync configured.
–
Status is reset automatically after the RPDO has been received again.
–
Setting of monitoring time for RPDO2 in 0x2304:055.
|
|
|
Bit
2
|
RPDO3-Timeout
|
1 = RPDO3 was not received within the monitoring time or not with the sync configured.
–
Status is reset automatically after the RPDO has been received again.
–
Setting of monitoring time for RPDO3 in 0x2304:065.
|
|
|
Bit
3
|
RPDO4-Timeout
|
1 = RPDO4 was not received within the monitoring time or not with the sync configured.
–
Status is reset automatically after the RPDO has been received again.
–
Setting of monitoring time for RPDO4 in 0x2304:075.
|
|
|
Bit
8
|
Heartbeat-Timeout Consumer 1
|
1 = within the "Heartbeat Consumer Time", no heartbeat telegram was received from node 1 to be monitored.
–
Status is automatically reset after the heartbeat telegram is received again.
–
"Heartbeat Consumer Time" setting in 0x2304:004.
|
|
|
Bit
9
|
Heartbeat-Timeout Consumer 2
|
1 = within the "Heartbeat Consumer Time", no heartbeat telegram was received from node 2 to be monitored.
–
Status is automatically reset after the heartbeat telegram is received again.
–
"Heartbeat Consumer Time" setting in 0x2304:005.
|
|
|
Bit
10
|
Heartbeat-Timeout Consumer 3
|
1 = within the "Heartbeat Consumer Time", no heartbeat telegram was received from node 3 to be monitored.
–
Status is automatically reset after the heartbeat telegram is received again.
–
"Heartbeat Consumer Time" setting in 0x2304:006.
|
|
|
Bit
11
|
Heartbeat-Timeout Consumer 4
|
1 = within the "Heartbeat Consumer Time", no heartbeat telegram was received from node 4 to be monitored.
–
Status is automatically reset after the heartbeat telegram is received again.
–
"Heartbeat Consumer Time" setting in 0x2304:007.
|
|
|
0x2308
|
CANopen status
–
Read only
|
Display of the current state.
|
|
|
0
|
Initialisation
|
Initialisation active.
–
The initialization is started automatically at mains connection. During this phase, the inverter us not involved in the data exchange process on the CAN bus.
–
When the initialization process has been completed, the inverter automatically adopts the "Pre-Operational" state.
|
|
|
1
|
Reset node
|
"Reset Node" NMT command active.
–
Initialization of all CANopen-relevant parameters with the saved settings.
|
|
|
2
|
Reset communication
|
"Reset Communication" NMT command active.
–
Initialization of all CANopen-relevant parameters with the saved settings.
|
|
|
4
|
Stopped
|
"Stop remote node" NMT command active.
–
Only network management telegrams can be received.
|
|
|
5
|
Operational
|
Parameter data and process data can be received. If defined, process data is sent as well.
|
|
|
127
|
Pre-Operational
|
Parameter data can be received, process data are ignored.
|
|
|
0x2309
|
CANopen controller status
–
Read only
|
Status display of the internal CANopen controller.
|
|
|
1
|
Error active
|
The inverter is a fully-fledged communication node
at the CANopen network. It is able to transmit and receive data
and to report faults.
|
|
|
2
|
Error passive
|
The inverter can only passively indicate faulty reception via
the ACK field.
|
|
|
3
|
Bus off
|
The inverter is electrically separated from the CANopen network.
In order to exit this state, the
CANopen interface must be reset. An automatic restart is implemented.
|
|
|
0x230A:001
|
CANopen statistics: PDO1 received
–
Read only
|
Display of the number of PDO1 telegrams received.
|
|
|
0x230A:002
|
CANopen statistics: PDO2 received
–
Read only
|
Display of the number of PDO2 telegrams received.
|
|
|
0x230A:003
|
CANopen statistics: PDO3 received
–
Read only
|
Display of the number of PDO3 telegrams received.
|
|
|
0x230A:004
|
CANopen statistics: POD3 recieved
–
Read only
|
Display of the number of received PDO4 telegrams.
|
|
|
0x230A:005
|
CANopen statistics: PDO1 transmitted
–
Read only
|
Display of the number of PDO1 telegrams sent.
|
|
|
0x230A:006
|
CANopen statistics: PDO2 transmitted
–
Read only
|
Display of the number of PDO2 telegrams sent.
|
|
|
0x230A:007
|
CANopen statistics: PDO3 transmitted
–
Read only
|
Display of the number of PDO3 telegrams sent.
|
|
|
0x230A:008
|
CANopen statistics: PDO4 transmitted
–
Read only
|
Display of the number of sent PDO4 telegrams.
|
|
|
0x230A:009
|
CANopen statistics: SDO1 telegrams
–
Read only
|
Display of the number of SDO1 telegrams.
|
|
|
0x230A:010
|
CANopen statistics: SDO2 telegrams
–
Read only
|
Display of the number of SDO2 telegrams.
|
|
|
0x230A:013
|
CANopen statistics: Sync - Deviation
–
Read only
|
||
|
0x230A:014
|
CANopen statistics: Sync - Phase position distance
–
Read only
|
||
|
0x230B
|
CANopen error counter
–
Read only
|
Display of the total number of CAN faults that have occurred.
|
|