Information on the network

Parameter
Address
Name / setting range / [default setting]
Information
0x2302:001
Active CANopen settings: Active node ID
–
Read only
 
Display of the active node address.
0x2302:002
Active CANopen settings: Active baud rate
–
Read only
 
Display of the active baud rate.
0
Automatic
1
20 kbps
2
50 kbps
3
125 kbps
4
250 kbps
5
500 kbps
6
800 kbps
7
1 Mbps
0x2307
CANopen time-out status
–
Read only
 
Bit-coded status display of the CAN time monitoring functions.
Bit  0
RPDO1-Timeout
1 = RPDO1 was not received within the monitoring time or not with the sync configured.
–
Status is reset automatically after the RPDO has been received again.
 
–
Setting of monitoring time for RPDO1 in 0x2304:045.
 
Bit  1
RPDO2-Timeout
1 = RPDO2 was not received within the monitoring time or not with the sync configured.
–
Status is reset automatically after the RPDO has been received again.
 
–
Setting of monitoring time for RPDO2 in 0x2304:055.
 
Bit  2
RPDO3-Timeout
1 = RPDO3 was not received within the monitoring time or not with the sync configured.
–
Status is reset automatically after the RPDO has been received again.
 
–
Setting of monitoring time for RPDO3 in 0x2304:065.
 
Bit  3
RPDO4-Timeout
1 = RPDO4 was not received within the monitoring time or not with the sync configured.
–
Status is reset automatically after the RPDO has been received again.
 
–
Setting of monitoring time for RPDO4 in 0x2304:075.
 
Bit  8
Heartbeat-Timeout Consumer 1
1 = within the "Heartbeat Consumer Time", no heartbeat telegram was received from node 1 to be monitored.
–
Status is automatically reset after the heartbeat telegram is received again.
 
–
"Heartbeat Consumer Time" setting in 0x2304:004.
 
Bit  9
Heartbeat-Timeout Consumer 2
1 = within the "Heartbeat Consumer Time", no heartbeat telegram was received from node 2 to be monitored.
–
Status is automatically reset after the heartbeat telegram is received again.
 
–
"Heartbeat Consumer Time" setting in 0x2304:005.
 
Bit  10
Heartbeat-Timeout Consumer 3
1 = within the "Heartbeat Consumer Time", no heartbeat telegram was received from node 3 to be monitored.
–
Status is automatically reset after the heartbeat telegram is received again.
 
–
"Heartbeat Consumer Time" setting in 0x2304:006.
 
Bit  11
Heartbeat-Timeout Consumer 4
1 = within the "Heartbeat Consumer Time", no heartbeat telegram was received from node 4 to be monitored.
–
Status is automatically reset after the heartbeat telegram is received again.
 
–
"Heartbeat Consumer Time" setting in 0x2304:007.
 
0x2308
CANopen status
–
Read only
 
Display of the current state.
0
Initialisation
Initialisation active.
–
The initialization is started automatically at mains connection. During this phase, the inverter us not involved in the data exchange process on the CAN bus.
 
–
When the initialization process has been completed, the inverter automatically adopts the "Pre-Operational" state.
 
1
Reset node
"Reset Node" NMT command active.
–
Initialization of all CANopen-relevant parameters with the saved settings.
 
2
Reset communication
"Reset Communication" NMT command active.
–
Initialization of all CANopen-relevant parameters with the saved settings.
 
4
Stopped
"Stop remote node" NMT command active.
–
Only network management telegrams can be received.
 
5
Operational
Parameter data and process data can be received. If defined, process data is sent as well.
127
Pre-Operational
Parameter data can be received, process data are ignored.
0x2309
CANopen controller status
–
Read only
 
Status display of the internal CANopen controller.
1
Error active
The inverter is a fully-fledged communication node at the CANopen network. It is able to transmit and receive data and to report faults.
2
Error passive
The inverter can only passively indicate faulty reception via the ACK field.
3
Bus off
The inverter is electrically separated from the CANopen network. In order to exit this state, the CANopen interface must be reset. An automatic restart is implemented.
0x230A:001
CANopen statistics: PDO1 received
–
Read only
 
Display of the number of PDO1 telegrams received.
0x230A:002
CANopen statistics: PDO2 received
–
Read only
 
Display of the number of PDO2 telegrams received.
0x230A:003
CANopen statistics: PDO3 received
–
Read only
 
Display of the number of PDO3 telegrams received.
0x230A:004
CANopen statistics: POD3 recieved
–
Read only
 
Display of the number of received PDO4 telegrams.
0x230A:005
CANopen statistics: PDO1 transmitted
–
Read only
 
Display of the number of PDO1 telegrams sent.
0x230A:006
CANopen statistics: PDO2 transmitted
–
Read only
 
Display of the number of PDO2 telegrams sent.
0x230A:007
CANopen statistics: PDO3 transmitted
–
Read only
 
Display of the number of PDO3 telegrams sent.
0x230A:008
CANopen statistics: PDO4 transmitted
–
Read only
 
Display of the number of sent PDO4 telegrams.
0x230A:009
CANopen statistics: SDO1 telegrams
–
Read only
 
Display of the number of SDO1 telegrams.
0x230A:010
CANopen statistics: SDO2 telegrams
–
Read only
 
Display of the number of SDO2 telegrams.
0x230A:013
CANopen statistics: Sync - Deviation
–
Read only
 
0x230A:014
CANopen statistics: Sync - Phase position distance
–
Read only
 
0x230B
CANopen error counter
–
Read only
 
Display of the total number of CAN faults that have occurred.