SSI encoder

SSI absolute value encoder (Synchronous Serial Interface) generate the angle information by optically scanning a code disc (e.g. as Gray Code). Each (absolute) angular position of the encoder corresponds to a code pattern that can be uniquely assigned.
 
All encoders that use the Stegmann SSI protocol are supported:
–
Supported bit rates for SSI communication: 150 ... 1000 kbits
 
–
Supported data word widths: 1 ... 31 bits (effective)
 
–
Supported output code of the SSI encoder: Gray or Binary
 
–
Cycle time: 62.5
µ
s, 125
µ
s and 250
µ
s .
 
–
Encoder supply: U < 12 V, I
≤
0.25 A
 
 
How to parameterise the SSI encoder:
 
1.
Set the supply voltage of the SSI encoder used in 0x2C52:002.
 
2.
Set selection "5: SSI encoder" as the encoder type in 0x2C50.
 
3.
Set the transmission rate for SSI communication in 0x2C5A:001.
With the SSI protocol, the permissible transmission rate decreases as the cable lengths increase. A safe transmission rate must be set according to the length of the encoder cable used and the electromagnetic interference level.
 
4.
Set the telegram length in 0x2C5A:002.
The telegram length reflects the number of data bits used for transmission of a complete SSI data packet.
 
5.
Break the received SSI data word down into partwords and, if necessary, activate data conversion of Gray into binary code.
 
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2C5A:001
Load encoder/master encoder (SSI) protocol parameters: Bit rate
150 ... [300] ... 1000 kbps
–
Setting can only be changed if the inverter is disabled.
 
To enable a stable transmission rate, the length of the encoder cable used and any electromagnetic interference levels must be taken into account when setting the value.
0x2C5A:002
Load encoder/master encoder (SSI) protocol parameters: Telegram length
1 ... [25] ... 31
–
Setting can only be changed if the inverter is disabled.
 
The set value specifies the number of data bits which are transmitted as a complete SSI data packet.
0x2C5A:003
Load encoder/master encoder (SSI) protocol parameters: Bits/revolution
1 ... [13] ... 31
–
Setting can only be changed if the inverter is disabled.
 
Resolution of the encoder.
For example, the resolution for the preset value is "13":
213 = 8196 (bits/revolution).
0x2C5A:004
Load encoder/master encoder (SSI) protocol parameters: Position data start bit
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
 
Indicates the position in the telegram where the position data word begins.
0x2C5A:005
Load encoder/master encoder (SSI) protocol parameters: Data package 1 start bit
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
 
Indicates the position in the telegram where data packet 1 begins.
0x2C5A:006
Load encoder/master encoder (SSI) protocol parameters: Data package 2 start bit
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
 
Indicates the position in the telegram where data packet 2 begins.
0x2C5A:007
Load encoder/master encoder (SSI) protocol parameters: Data package 3 start bit
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
 
Indicates the position in the telegram where data packet 3 begins.
0x2C5A:008
Load encoder/master encoder (SSI) protocol parameters: Position data length
0 ... [25] ... 30
–
Setting can only be changed if the inverter is disabled.
 
SSI position data length
0x2C5A:009
Load encoder/master encoder (SSI) protocol parameters: Data package 1 length
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
 
Length of data packet 1.
0x2C5A:010
Load encoder/master encoder (SSI) protocol parameters: Data package 2 length
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
 
Length of data packet 2.
0x2C5A:011
Load encoder/master encoder (SSI) protocol parameters: Data package 3 length
0 ... [0] ... 30
–
Setting can only be changed if the inverter is disabled.
 
Length of data packet 3.
0x2C5A:012
Load encoder/master encoder (SSI) protocol parameters: Position data coding
–
Setting can only be changed if the inverter is disabled.
 
Coding of position data word (read only).
If a value of "0" is set for the position data length in 0x2C4A:008, then the value displayed for this parameter is also "0".
0
Binary
1
Gray
0x2C5A:013
Load encoder/master encoder (SSI) protocol parameters: Data package 1 coding
–
Setting can only be changed if the inverter is disabled.
 
Coding of data packet 1
0
Binary
1
Gray
0x2C5A:014
Load encoder/master encoder (SSI) protocol parameters: Data package 2 coding
–
Setting can only be changed if the inverter is disabled.
 
Coding of data packet 2
0
Binary
1
Gray
0x2C5A:015
Load encoder/master encoder (SSI) protocol parameters: Data package 3 coding
–
Setting can only be changed if the inverter is disabled.
 
Coding of data packet 3
0
Binary
1
Gray
0x2C5A:016
Load encoder/master encoder (SSI) protocol parameters: Position raw data
–
Read only
 
Raw value of position data word (read only).
If a value of "0" is set for the position data length in 0x2C4A:008 , then the value displayed for this parameter is also "0".
0x2C5A:017
Load encoder/master encoder (SSI) protocol parameters: Data package 1 raw data
–
Read only
 
Raw value of data packet 1 (read only).
If a value of "0" is set for the data packet length 1 in 0x2C4A:013 , then the value displayed for this parameter is also "0".
0x2C5A:018
Load encoder/master encoder (SSI) protocol parameters: Data package 2 raw data
–
Read only
 
Raw value of data packet 2 (read only).
If a value of "0" is set for the data packet length 2 in 0x2C4A:014 , then the value displayed for this parameter is also "0".
0x2C5A:019
Load encoder/master encoder (SSI) protocol parameters: Data package 3 raw data
–
Read only
 
Raw value of data packet 3 (read only).
If a value of "0" is set for the data packet length 3 in 0x2C4A:015 , then the value displayed for this parameter is also "0".
0x2C5A:020
Load encoder/master encoder (SSI) protocol parameters: Encoder type
–
Setting can only be changed if the inverter is disabled.
 
0
Rotative encoder
1
Linear encoder
0x2C5A:021
Load encoder/master encoder (SSI) protocol parameters: Position raw data scaled by 0x608F
–
Read only
 
0x2C5A:022
Load encoder/master encoder (SSI) protocol parameters: Monoflop time
0 ... [0] ... 500
–
Setting can only be changed if the inverter is disabled.
 
0x2C5A:023
Load encoder/master encoder (SSI) protocol parameters: Resulting SSI-telegram cycle time
–
Read only