SinCos absolute value encoder with HIPERFACE® protocol
The following SinCos encoder types with HIPERFACE
®
protocol are supported by the inverter:|
Type
|
Increments/revolution
|
Absolute revolutions
|
Type code
|
|
AM1024-8V-H (SRM50)
|
1024
|
4096
(Multiturn)
|
39
|
|
AM1024-8V-H (SFM60)
|
1024
|
39
|
|
|
AM1024-8V-K2 (SRM50S)
|
1024
|
39
|
|
|
AM128-8V-H (SKM36)
|
128
|
55
|
|
|
AM16-8V-H (SEL37)
|
16
|
71
|
|
|
AM16-8V-H (SEL52)
|
16
|
71
|
|
|
AM512-8V-H (SCM70)
|
512
|
7
|
|
|
AS1024-8V-H (SRS50)
|
1024
|
4096
(Single-turn)
|
34
|
|
AS1024-8V-K2 (SRS50S)
|
1024
|
34
|
|
|
AS16-8V-H (SEK37)
|
16
|
66
|
|
|
AS16-8V-H (SEK52)
|
16
|
66
|
|
|
AS512-8V-H (SCS70)
|
512
|
2
|
Use of non-supported encoder types
If the type code of the encoder used is not listed in the table of supported encoder types, this encoder can be introduced to the inverter via two parameters.
0x2C51:002
0x2C51:003
0x2C51:002
0x2C51:003In this context, please also observe the information provided in the parameter description 0x2C41:008.
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2822:030
|
Axis commands: Get load encoder/master encoder information (HIPERFACE®)
|
Obtain Hiperface information from the encoder for application feedback.
|
|
|
0
|
Off/Ready
|
||
|
1
|
On/Start
|
||
|
2
|
In progress
|
||
|
3
|
Action cancelled
|
||
|
4
|
No access
|
||
|
5
|
No access (controller inhibit)
|
||
|
0x2C51:001
|
Load encoder/master encoder settings (HIPERFACE®): Type code detected
–
Read only
|
Type code read out of the encoder.
This value is "0" if ...
|
|
|
0x2C51:002
|
Load encoder/master encoder settings (HIPERFACE®): Type code manual input
0 ... [0] ... 255
–
Setting can only be changed if the inverter is disabled.
|
Manual setting of the encoder type code (display in 0x2C51:001).
|
|
|
0x2C51:003
|
Load encoder/master encoder settings (HIPERFACE®): Manual input - Number of detectable load/master encoder revolutions
1 ... [1] ... 65535
–
Setting can only be changed if the inverter is disabled.
|
Manual setting of the number of distinguishable revolutions.
|
|
|
0x2C51:004
|
Load encoder/master encoder settings (HIPERFACE®): Error response
|
Selection of the response for communication errors or in the event of an unknown encoder.
Associated event IDs:
–
537490306 | 0x20097382 - Load encoder/master encoder - Communication error
–
537490307 | 0x20097383 - Load encoder/master encoder - wrong absolute value because motor speed is too high
–
537526042 | 0x2009FF1A - Connected HIPERFACE® load encoder/master encoder is not supported
|
|
|
0
|
No response
|
||
|
1
|
Fault > CiA402
|
||
|
2
|
Warning
|
||
|
0x2C51:005
|
Load encoder/master encoder settings (HIPERFACE®): Serial number
–
Read only
|
The displayed serial number can be used for identifying an encoder change.
|
|
|
0x2C51:006
|
Load encoder/master encoder settings (HIPERFACE®): Actual position (raw data)
–
Read only
|
The encoder-internal position value is output without being converted.
|
|
|
0x2C51:007
|
Load encoder/master encoder settings (HIPERFACE®): No. of periods detected
–
Read only
|
Display of the encoder increment according to encoder nameplate or type code.
|
|
|
0x2C51:008
|
Load encoder/master encoder settings (HIPERFACE®): Type code verification
–
Read only
|
If an encoder is connected that is not supported by the firmware, it will be displayed here.
In this case, the same response takes place as in case of a communication error. The error can be removed by manually setting the type code in 0x2C51:002. This serves to signalise to the firmware that the number of distinguishable revolutions is as well set correctly in 0x2C51:003 by the user.
|
|
|
0
|
Unknown - manual data input
|
In this case, the same response takes place as in case of a communication error. The error can be removed by manually setting the type code in 0x2C51:002. This serves to signalise to the firmware that the number of distinguishable revolutions is as well set correctly in 0x2C51:003 by the user.
|
|
|
1
|
Known - parameterisation ok
|
||
|
0x2C51:009
|
Load encoder/master encoder settings (HIPERFACE®): Encoder type
–
Read only
|
Display of the detected encoder type (rotary/linear).
|
|
|
0
|
Rotative encoder
|
||
|
1
|
Linear encoder
|
||
|
0x2C51:010
|
Load encoder/master encoder settings (HIPERFACE®): Period length linear encoder
–
Read only: x nm
|
Display of the period length of the linear encoder.
|
|
Severity