Control signals

Parameter
Address
Name / setting range / [default setting]
Information
0x5030:010
Control signals
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Control signals
Bit  0
Control bit 00 (reserved)
Bit without function
Bit  1
Control bit 01 (reserved)
Bit  2
Activate application quick stop
Rotating drive is stopped via the quick stop ramp. The drive remains controlled at standstill.
Bit  3
Enable operation
Drive is enabled. With a LOW level, a rotating drive is stopped via the quick stop ramp and is inhibited at a standstill.
Bit  4
Control bit 04 (reserved)
Bit without function
Bit  5
Manual jog positive
In manual operation, the drive travels in positive direction. The drive stops when the positive software limit switch is reached.
Bit  6
Manual jog negative
In manual operation, the drive travels in negative direction. The drive stops when the negative software limit switch is reached.
Bit  7
Fault reset
Errors are reset when the causes are eliminated.
Bit  8
Halt
A stop is triggered in the application.
Bit  9
Start homing
Start homing.
Bit  10
Reset home position
Reset status information "home position known".
Bit  11
Abort
–
The active movement is canceled.
 
–
The axis is guided to standstill via the active profile deceleration.
 
–
The axis changes to "STOP".
 
The deceleration is canceled when a new movement is instructed.
Bit  12
Control bit 12 (reserved)
Bit without function
Bit  13
Activate velocity overrride
External speed override is activated.
Bit  14
Open brake manually
The holding brake is opened.
Bit  15
Control bit 15 (reserved)
Bit without function
Bit  16
Profile number bit 0
These bits are used for the bit-coded profile selection.
Bit 0 represents the decimal 1.
Bit 1 represents the decimal 2.
Bit 2 represents the decimal 4.
Bit 3 represents the decimal 8.
Bit  17
Profile number bit 1
Bit  18
Profile number bit 2
Bit  19
Profile number bit 3
Bit  20
Enable velocity operation
The speed operation is started.
Bit  21
Invert direction of rotation
The rotating direction is inverted.
Bit  22
Disable PID controller
The PID controller is deactivated.
Bit  23
Control bit 23 (reserved)
Bit without function
Bit  24
Control bit 24 (reserved)
Bit  25
Control bit 25 (reserved)
Bit  26
Control bit 26 (reserved)
Bit  27
Control bit 27 (reserved)
Bit  28
Activate external velocity offset
The external velocity offset is activated.
Bit  29
Activate profile velocity
The external profile speed is used.
Bit  30
Activate external acceleration/deceleration/jerk
External acceleration and decleration values and an external jerk are activated.
Bit  31
Activate external torque limits
The external torque limits are activated.
0x5030:011
External velocity override
0.00 ... [0.00] ... 100.00 %
Change of the profile speed during a positioning process.
0x5030:012
External velocity
-214748.3648 ... [0.0000] ... 214748.3647
Value for the external setpoint velocity.
0x5030:013
External velocity offset
-214748.3648 ... [0.0000] ... 214748.3647
Value for the external velocity offset.
0x5030:014
External acceleration
0.00 ... [0.00] ... 21474836.47
Value for the external acceleration.
0x5030:015
External deceleration
0.00 ... [0.00] ... 21474836.47
Value for the external deceleration.
0x5030:016
External jerk
0.00 ... [0.00] ... 21474836.47
Value for the external jerk.
0x5030:017
External torque limit
0.00 ... [0.00] ... 21474836.47 %
Value of the external torque limit.
Reference: Rated motor torque0x6076