Status signals

Parameter
Address
Name / setting range / [default setting]
Information
0x5030:110
Status signals
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Bit  0
Ready for operation
Axis ready for switch-on.
Bit  1
Homing active
Homing is active.
Bit  2
Operation enabled
Axis is enabled.
Bit  3
Fault
An error is active.
Bit  4
Homing done
Homing was completed successfully.
Bit  5
Application quick stop active
Quick stop was triggered.
Bit  6
Manual jog active
Manual operation is active.
Bit  7
Warning
A warning is active.
Bit  8
Halt active
A stop was triggered in the application.
Bit  9
Motor control in limitation
The motor control is in limitation.
Bit  10
Set velocity reached
Actual velocity = setpoint velocity
Bit  11
Abort busy
The active movement is canceled.
Bit  12
Standstill
Standstill reached.
Bit  13
Direction of rotation inverted
Direction of rotation is inverted.
Bit  14
Brake opened
The holding brake is open.
Bit  15
STO active
Safe Torque Off is active.
Bit  16
Active profile bit 0
Active profile (bit-coded).
Bit 0 represents the decimal 1.
Bit 1 represents the decimal 2.
Bit 2 represents the decimal 4.
Bit 3 represents the decimal 8.
Bit  17
Active profile bit 1
Bit  18
Active profile bit 2
Bit  19
Active profile bit 3
Bit  20
Velocity operation active
Speed operation is active.
Bit  21
Setpoint generation done
Ramp generation completed.
Bit  22
PID controller active
The PID controller is active.
Bit  23
Status bit 23 (reserved)
Bit without function
Bit  24
Status bit 24 (reserved)
Bit  25
Status bit 25 (reserved)
Bit  26
Status bit 26 (reserved)
Bit  27
Torque setpoint limited
The setpoint torque is in limitation.
Bit  28
External velocity offset active
The external velocity offset is active.
Bit  29
Profile velocity active
A profile velocity is active.
Bit  30
External acceleration/deceleration/jerk active
External acceleration values, external deceleration values, and the external jerk are active.
Bit  31
External torque limit active
The external torque limits are active.
0x5030:111
Status signals limiter
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
Extended Safety - status of the monitoring functions
Bit  0
STO active
Safe torque off (STO) active.
The axis is safely switched to torqueless operation.
Bit  1
SS1 active
Safe stop 1 (SS1) active.
Subsequently, the drive is torqueless (STO).
Bit  2
SS2 active
Safe stop 2 (SS2) active.
The drive then changes to the safe operational stop (SOS).
Bit  3
SOS active
Safe operational stop (SOS) active.
The reached position is actively held.
Bit  4
SLS1 active
Safely limited speed (SLS1) active.
The travel profile changes according to the parameters set for it.
Bit  5
SLS2 active
Safely limited speed (SLS2) active.
The travel profile changes according to the parameters set for it.
Bit  6
SLS3 active
Safely limited speed (SLS3) active.
The travel profile changes according to the parameters set for it.
Bit  7
SLS4 active
Safely limited speed (SLS4) active.
The travel profile changes according to the parameters set for it.
Bit  8
SDpos active
Safe direction (SDI) active.
Only the positive direction is allowed.
Bit  9
SDneg active
Safe direction (SDI) active.
Only the negative direction is allowed.
Bit  10
SLI active
Safely limited increment (SLI) active.
A maximum permissible change in position is monitored.
Bit  11
SSE active
Safe stop emergency (SSE) active.
Bit  12
ES active
Enable switch (ES) active.
The stop functions in special mode are overridden.
Bit  13
OMS active
Operation mode selector (OMS) active.
Special operation is active.
0x5030:112
Actual velocity
-214748.3648 ... [0.0000] ... 214748.3647
Display of the actual velocity
0x5030:113
Status word 3 (reserved)
-214748.3648 ... [0.0000] ... 214748.3647
Word without function
0x5030:114
Error code
0 ... [0] ... 4294967295
Display of the current error number.
0x5030:115
Actual torque
-214748.3648 ... [0.0000] ... 214748.3647 Nm
Display of the actual torque
0x5030:116
Display value 1
0 ... [0] ... 4294967295
Display of the monitor signal "Display value 1"
Selection: 0x5030:006
0x5030:117
Display value 2
0 ... [0] ... 4294967295
Display of the monitor signal "Display value 2"
Selection: 0x5030:007