External travel profile parameters

Acceleration, deceleration and jerk values can be defined via one of 15 travel profiles or via external control signals.
Fig. 1: Using external acceleration and deceleration values
Fig. 2: Control and status bits used
Execution
–
Control bit 30 must be set to TRUE for this purpose.0x5030:010 Bit 30
 
–
Status bit 30 indicates whether this function is active.0x5030:110 Bit 30
 
–
The values are defined via the following parameters:
 
–
0x5030:014 (External acceleration)
 
–
0x5030:015 (External deceleration)
 
–
0x5030:016 (External jerk)
 
 
–
The acceleration, deceleration and jerk values are resolved with two decimal positions. For instance, if an acceleration of 100 [units/s²] is to be specified, the value 10000 must be specified via the External acceleration parameter.
 
–
The parameters displayed for the setpoint acceleration, setpoint deceleration and setpoint jerk are as follows:
 
–
0x5032:022 (Setpoint acceleration)
 
–
0x5032:023 (Setpoint deceleration)
 
–
0x5032:024 (Setpoint jerk)
 
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x5030:012
External velocity
-214748.3648 ... [0.0000] ... 214748.3647
Value for the external setpoint velocity.
0x5030:014
External acceleration
0.00 ... [0.00] ... 21474836.47
Value for the external acceleration.
0x5030:015
External deceleration
0.00 ... [0.00] ... 21474836.47
Value for the external deceleration.
0x5030:016
External jerk
0.00 ... [0.00] ... 21474836.47
Value for the external jerk.
0x5032:021
Velocity setpoint
–
Read only
 
0x5032:022
Acceleration setpoint
–
Read only
 
0x5032:023
Deceleration setpoint
–
Read only
 
0x5032:024
Jerk setpoint
–
Read only
 
 
Example
The following example shows the use of the External acceleration and External deceleration control signals.
The two control signals are activated via control bit 30.
The preselected setpoint velocity is 1000 units/s and the axis is accelerated at a rate of 100 units/s2 based on the profile data. During the acceleration phase, the external acceleration and deceleration values are activated (external acceleration = external deceleration = 1000 units/s2). As a result of this change-over, the external values start being used immediately.
The Setpoint acceleration and Setpoint deceleration signal flow parameters show which acceleration and deceleration values are active. When the setpoint velocity has been reached, the external values are deactivated again. The profile data are then active again.
The setpoint velocity is set to zero. The axis starts to decelerate at 100 units/s2. During the delay, the external values are activated again. The axis is guided to standstill with a deceleration of 1000 units/s2.
Fig. 3: Setpoint velocity timing diagram