Path-controlled clutch

The paths for the path-controlled clutch can be set as follows:
The clutch engagement path is configured via the Clutch-in distance parameter. 0x5041:035
The clutch disengagement path is configured via the Declutch distance parameter. 0x5041:036

The initial parameter values are such that the clutch process is complete after 90 path units of the drive axis.
After the clutch is disengaged, the drive is in the Declutch position.

0x5041:033
Fig. 1: Engage clutch with clutching mode = 5
Fig. 2: Disengage clutch with clutching mode = 5
 
Relevant parameters of other functions
Address
Name
Default setting
Setting range
Allowed direction
Positive direction [1]
Selection list
Declutch position
0.0000
0.0000 ... 214748.3647
Deceleration of "direct declutching"
5.0000
0.0000 ... 214748.3647
Clutch-in distance
90.0000
0.0000 ... 214748.3647
Declutch distance
90.0000
0.0000 ... 214748.3647