Path-controlled clutch
The paths for the path-controlled clutch can be set as follows:
The clutch engagement path is configured via the Clutch-in distance parameter.
0x5041:035
0x5041:035The clutch disengagement path is configured via the Declutch distance parameter.
0x5041:036
0x5041:036The initial parameter values are such that the clutch process is complete after 90 path units of the drive axis.
After the clutch is disengaged, the drive is in the Declutch position.
0x5041:033Fig. 1: Engage clutch with clutching mode = 5
Fig. 2: Disengage clutch with clutching mode = 5
Relevant parameters of other functions
|
Address
|
Name
|
Default setting
|
Setting range
|
|
Allowed direction
|
Positive direction [1]
|
Selection list
|
|
|
Declutch position
|
0.0000
|
0.0000 ... 214748.3647
|
|
|
Deceleration of "direct declutching"
|
5.0000
|
0.0000 ... 214748.3647
|
|
|
Clutch-in distance
|
90.0000
|
0.0000 ... 214748.3647
|
|
|
Declutch distance
|
90.0000
|
0.0000 ... 214748.3647
|