Travel profile-based clutch
The engage and disengage clutch variant is independent from a master value movement. This means that the drive axis is also synchronised if the master value is standing.
Engage clutch
The drive axis engages to the master position from its current position via the profile generator with the following listed parameters.
–
Clutch velocity
0x5041:039
0x5041:039–
Clutch acceleration
0x5041:040
0x5041:040–
Clutch deceleration
0x5041:041
0x5041:041–
Clutch jerk
0x5041:042
0x5041:042In the clutch engagement phase, the velocity of the drive axis results from the sum of the velocity of the master axis and the Clutch velocity.
0x5041:039
0x5041:039 In the clutch engagement phase, the velocity of the slave axis results from the sum of the velocity of the master value and the acceleration or deceleration of the clutch.
Fig. 1: Clutch engages with eSyncMode = 4 Ramp_Time
Disengage clutch
The Declutch time parameter defines the stopping position and the time in which the drive axis begins to disengage from its current position. 0x5041:038
The profile-controlled disengagement of the clutch leads the drive axis from its current position to standstill with the following parameters:
–
Clutch velocity
0x5041:039
0x5041:039–
Clutch acceleration
0x5041:040
0x5041:040–
Clutch deceleration
0x5041:041
0x5041:041–
Clutch jerk
0x5041:042
0x5041:042 The Declutch position parameter defines the stopping position of the drive axis.
0x5041:033
0x5041:033Fig. 2: Coupling disengages with eSyncMode = 4 Ramp_Time
Relevant parameters of other functions
|
Address
|
Name
|
Default setting
|
Setting range
|
|
Declutch position
|
0.0000
|
0.0000 ... 214748.3647
|
|
|
Clutch velocity
|
100.0000
|
0.0000 ... 214748.3647
|
|
|
Clutch acceleration
|
1000.0000
|
0.0000 ... 214748.3647
|
|
|
Clutch deceleration
|
1000.0000
|
0.0000 ... 214748.3647
|
|
|
Clutch jerk
|
10000.0000
|
0.0000 ... 214748.3647
|