Parameterization
The method of vibration compensation needs the information about the natural frequency of the mast as well as the damping of the vibration.
The natural frequency as well as the damping of the mast depends on the height of the load handling device and its load.
The parameterization is done via a (4,2) matrix. The matrix is a structure that contains the data of the natural frequency and the damping. Thus, a maximum of four data sets can be defined depending on the position of the mast and a maximum of two data sets depending on the load.
The supporting points for the positions of the mast are defined by an array 1 to 4 with scPar.ascOscCompPosScaled[1to4].
The input of the position of the mast is scaled in the range from 0 to 1. The value 0 corresponds to the position of the lower SW end position and the value 1 to the upper SW end position.
In the following example, 2 out of 4 position handles are activated:
scPar.ascOscCompPosScaled[1].xValid := TRUE;
scPar.ascOscCompPosScaled[1].lrValue := 0.0;
scPar.ascOscCompPosScaled[2].xValid := TRUE;
scPar.ascOscCompPosScaled[2].lrValue := 1.0;
scPar.ascOscCompPosScaled[3].xValid := FALSE;
scPar.ascOscCompPosScaled[3].lrValue := 0.0;
scPar.ascOscCompPosScaled[4].xValid := FALSE;
scPar.ascOscCompPosScaled[4].lrValue := 0.0;
The supporting point is switched active with scPar.ascOscCompPosScaled[idx].xValid. The value of the breakpoint is passed via scPar.ascOscCompPosScaled[idx].lrValue.
The supporting points for the loading are defined via an array 1 to 2 with scPar. ascOscCompLoadScaled [1 to 2].
In the following example, 2 out of 2 support points are activated for loading:
scPar.ascOscCompLoadScaled[1].xValid := TRUE;
scPar.ascOscCompLoadScaled[1].lrValue := 0.0;
scPar.ascOscCompLoadScaled[2].xValid := TRUE;
scPar.ascOscCompLoadScaled[2].lrValue := 0.0;
For each data set, the natural frequency and the damping are to be specified as a function of the height of the load handling device and its load. The data set with the natural frequency and the damping is done via a 2dim array using scPar.ascOscCompPar[1..2, 1..4]. Via index 1 the interpolation points are defined depending on the load and via index 2 the interpolation points are defined depending on the position. scPar.ascOscCompPar[loadScaled,posScaled].
In the following example 2 times 2 data sets of damping and natural frequency are defined:
/// loadScaled = 0, posScaled = 0
scPar.ascOscCompPar[1,1]. lrEigenFrequency := 2.8;
scPar.ascOscCompPar[1,1]. lrAmpRatio := 0.5;
/// loadScaled = 0, posScaled = 1
scPar.ascOscCompPar[1,2]. lrOwnFrequency := 1.2;
scPar.ascOscCompPar[1,2]. lrAmpRatio := 0.7;
/// loadScaled = 1, posScaled = 0
scPar.ascOscCompPar[2,1]. lrEigenFrequency := 2.8;
scPar.ascOscCompPar[2,1]. lrAmpRatio := 0.5;
/// loadScaled = 1, posScaled = 1
scPar.ascOscCompPar[2,2]. lrOwnFrequency := 1;
scPar.ascOscCompPar[2,2]. lrAmpRatio := 0.75;
Summarized data sets from the extract of the visualization of the technology module:
Parameters to be set
|
Identifier Data type |
Value Data type |
Description |
|---|---|---|
|
ascOscCompLoadScaled ARRAY[1..2] OF L_TV2P_ValidValue |
xValid BOOL |
TRUE: the value lrValue is valid and active FALSE: the value lrValue is disabled. |
|
lrValue BOOL |
Base point of the scaled loading: Value range 0 to 1 Default 0 |
|
|
ascOscCompPosScaled ARRAY[1..4] OF L_TV2P_ValidValue |
xValid BOOL |
TRUE: the value lrValue is valid and active FALSE: the value lrValue is disabled. |
|
lrValue LREAL |
Interpolation point of the scaled position of the y-axis:
|
|
|
ascOscCompPar ARRAY[1..2,1..4] OF L_TV2P_OscillationCompensationPar |
lrEigenFrequency LREAL |
Natural frequency in Hz |
|
lrAmpRatio LREAL |
Damping of the vibration |
The resulting natural frequency and amplitude ratio are determined using bilinear interpolation and cubic spline interpolation from the key data of position and loading, and adjusted for the vibration suppression function.
The position for the interpolation of the basic data is automatically scaled between end positions via the position of the y-axis for the TM and used for the cubic spline interpolation. The load is set via the input lrOscCompLoadScaled (setting range 0 ... 1 with 1 = 100 %) at the TM "Stacker Crane Axis Control".
In case there is no connection to the TM StackerCrane y-axis, the position is set via the input lrOscCompPosScaled (setting range 0 ... 1 with 1 = 100 %) at the TM "Stacker Crane Axis Control".
At least two data sets must be defined in the dependency of the height of the load taking means, so that the bilinear interpolation can be calculated.
During the travel of the trolley, the height of the load receptor also changes and thus the currently valid input frequency. By using several data sets, the change of the input frequency and the change of the damping in dependence on the LAM height can also be taken into account during the travel.
Important note: It must be ensured that the change in natural frequency and damping within the data table is uniformly increasing or decreasing. There must be no inflection points of the gradient within the table! Otherwise the spline interpolation would calculate an incorrect dependency of the frequency on the position and the vibration compensation would not function correctly.