Use module coupling

Disconnecting a machine module from its higher-level module means that the operation mode of the disconnected module no longer follows the master, but can be set independently.

Example

The following structure consists of a machine module MachineControl and two subordinate modules SlaveA and SlaveB . The SlaveA module is to be decoupled.

The MMD.xDisableCoupling signal of the SlaveA module is set to TRUE.

This signal is present at the xDisableCoupling input of the OpModeControl function block in the MFB_SlaveA.BF01_BasicFunction action. s

The xCouplingDisabled output on the same module shows the current status of the module coupling for the module.

The visualisation L_Main contains the identifier "DIS" for the decoupled module SlaveA in the "CPL" column of the module list.

The operation mode of the SlaveA module can now be controlled independently of the higher-level MachineControl module via the inputs of the OpModeAccess block (action MFB_SlaveA._ BF01_BasicFunction ).

To restore the coupling, the MMD.xDisableCoupling signal is reset to the default value FALSE. As soon as the two machine modules involved have the same operation mode, the coupling is restored.