EoE communication

The "Ethernet over EtherCAT (EoE)" is used to send standard Ethernet telegrams via the EtherCAT network without affecting the real-time communication of the EtherCAT process data. This extension facilitates the set-up of parameter communication (SDO communication) with the inverters on the EtherCAT bus by means of a standard Ethernet connection (e.g. from a PC with »EASY Starter«).
System architecture
Beckhoff controller
Lenze / other controllers
ESD - Slave bridge
 
Supported protocols and services
–
ARP
 
–
DHCP
 
–
ICMP (ping)
 
–
UDP/TCP
 
–
GCI-SDO communication
 
 
Display of EoE-specific information
The following table can be used to read EoE-specific information for diagnostic purposes.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2362:001
(P511.01)
Active EtherCAT settings: EoE IP address
(EtherCAT diag.: EoE IP address)
–
Read only
 
0x2362:002
(P511.02)
Active EtherCAT settings: EoE subnet mask
(EtherCAT diag.: EoE subnet mask)
–
Read only
 
–
From version 05.01
 
0x2362:003
(P511.03)
Active EtherCAT settings: EoE gateway
(EtherCAT diag.: EoE gateway)
–
Read only
 
0x2362:005
(P511.05)
Active EtherCAT settings: EoE virtual MAC address
(EtherCAT diag.: EoE virt MAC add)
–
Read only
 
–
From version 02.00