POWERLINK
POWERLINK is a real-time capable fieldbus system based on Ethernet.
–
Information about the dimensioning of a POWERLINK network can be found in the configuration document for the inverter.
Preconditions
–
The control unit (CU) of the inverter is provided with POWERLINK.
Features
The inverter is implemented as a controlled node (CN) in a POWERLINK network. It may only respond to poll-request messages of a managing node (MN). See "Typical topologies" section.
–
The network option can both be supplied internally by the standard device and externally by a separate voltage source.
–
Real time Ethernet with the Ethernet POWERLINK V2 communication profile for Motion and general applications
–
A line topology can be set up by the integrated 2-port hub.
–
Supported functionalities: POWERLINK CN
–
Very short CN response times for optimum network performance
–
Access to all inverter parameters
The following is not supported:
–
Firmware download via POWERLINK
–
PDO crosslinks for the managing node or the controlled node for setting up systems with "distributed intelligence"
Typical topology
|
Line
|
|
|
|
Mrated
|
Managing Node
|
H
|
Hub
|
|
CN
|
Controlled Node
|
|
|