Analog signal 2

Intended use
The analog signal 2 can be used for the following tasks:
–
As a standard setpoint source
 
Intended use
Parameter
Setting
Further information
As a setpoint source for specifying a frequency setpoint.
Scaling2 value [231]
Frequency control Standard setpoint source 
As setpoint source for defining the reference value for the process controller.
Scaling2 value [231]
As a setpoint source for specifying a torque setpoint.
Scaling2 value [231]
Torque control Standard setpoint source 
–
As an actual value source or speed feedforward source for the process controller:
 
Intended use
Parameter
Setting
Further information
As an actual value source for the process controller.
Scaling2 value [231]
As a speed feedforward source for the process controller.
Scaling2 value [231]
 
Details
Configuration for analog signal 2:
①
Source address
③
Scaling
⑤
Optional mapping of the scaled analog signal to a parameter of the inverter
②
Source value
④
Value scaled
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2654:016
Analog signal scaling: Scaling2 source address
0 ... [0] ... 4294967295
Address of the parameter whose value is to be used as analog input value for scaling.
0x2654:017
Analog signal scaling: Scaling2 source value
–
Read only
 
Display of the unscaled value.
0x2654:018
Analog signal scaling: Scaling2 target address
0 ... [0] ... 4294967295
Optional mapping of the scaled value to a parameter of the inverter
0x2654:019
Analog signal scaling: Scaling2 scaled value
–
Read only
 
Display of the scaled value.
0x2654:020
Analog signal scaling: Scaling2 data type input
0
Signed
1
Unsigned
0x2654:021
Analog signal scaling: Scaling2 bits input
2 ... [16] ... 32
Number of the valid bits.
0x2654:022
Analog signal scaling: Scaling2 #A1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2654:023
Analog signal scaling: Scaling2 #A2max
-2147483648 ... [65535] ... 2147483647
0x2654:024
Analog signal scaling: Scaling2 data type output
0
Signed
1
Unsigned
0x2654:025
Analog signal scaling: Scaling2 bits output
2 ... [16] ... 32
Number of the valid bits.
0x2654:026
Analog signal scaling: Scaling2 #B1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2654:027
Analog signal scaling: Scaling2 #B2max
-2147483648 ... [65535] ... 2147483647
0x2654:030
Analog signal scaling: Scaling2 status
–
For further possible settings, see parameter 0x2652:015.
 
0
Inactive