Analog signal 1

In the default setting, the input frequency of the HTL input (0x2642:001) is set as the input value for scaling.
 
 
Intended use
The analog signal 1 can be used for the following tasks:
–
As a standard setpoint source
 
Intended use
Parameter
Setting
Further information
As a setpoint source for specifying a frequency setpoint.
Scaling1 value [230]
Frequency control Standard setpoint source 
As setpoint source for defining the reference value for the process controller.
Scaling1 value [230]
As a setpoint source for specifying a torque setpoint.
Scaling1 value [230]
Torque control Standard setpoint source 
–
As an actual value source or speed feedforward source for the process controller:
 
Intended use
Parameter
Setting
Further information
As an actual value source for the process controller.
Scaling1 value [230]
As a speed feedforward source for the process controller.
Scaling1 value [230]
 
Details
Configuration for analog signal 1:
①
Source address
③
Scaling
⑤
Optional mapping of the scaled analog signal to a parameter of the inverter
②
Source value
④
Value scaled
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2654:001
Analog signal scaling: Scaling1 source address
0 ... [641859872] ... 4294967295
Address of the parameter whose value is to be used as analog input value for scaling.
0x2654:002
Analog signal scaling: Scaling1 source value
–
Read only
 
Display of the unscaled value.
0x2654:003
Analog signal scaling: Scaling1 target address
0 ... [0] ... 4294967295
Optional mapping of the scaled value to a parameter of the inverter
0x2654:004
Analog signal scaling: Scaling1 scaled value
–
Read only
 
Display of the scaled value.
0x2654:005
Analog signal scaling: Scaling1 data type input
0
Signed
1
Unsigned
0x2654:006
Analog signal scaling: Scaling1 bits input
2 ... [32] ... 32
Number of the valid bits.
0x2654:007
Analog signal scaling: Scaling1 #A1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2654:008
Analog signal scaling: Scaling1 #A2max
-2147483648 ... [65535] ... 2147483647
0x2654:009
Analog signal scaling: Scaling1 data type output
0
Signed
1
Unsigned
0x2654:010
Analog signal scaling: Scaling1 bits output
2 ... [32] ... 32
Number of the valid bits.
0x2654:011
Analog signal scaling: Scaling1 #B1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2654:012
Analog signal scaling: Scaling1 #B2max
-2147483648 ... [65535] ... 2147483647
0x2654:015
Analog signal scaling: Scaling1 status
–
For further possible settings, see parameter 0x2652:015.
 
0
Inactive