0x24F0:000
|
Logic PLC RPDO mapping: Highest subindex
0 ... [0] ... 16
–
Setting can only be changed if the inverter is disabled.
|
|
|
0x24F0:001
|
Logic PLC RPDO mapping: Entry 1
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:002
|
Logic PLC RPDO mapping: Entry 2
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:003
|
Logic PLC RPDO mapping: Entry 3
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:004
|
Logic PLC RPDO mapping: Entry 4
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:005
|
Logic PLC RPDO mapping: Entry 5
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:006
|
Logic PLC RPDO mapping: Entry 6
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:007
|
Logic PLC RPDO mapping: Entry 7
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:008
|
Logic PLC RPDO mapping: Entry 8
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:009
|
Logic PLC RPDO mapping: Entry 9
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:010
|
Logic PLC RPDO mapping: Entry 10
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:011
|
Logic PLC RPDO mapping: Entry 11
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:012
|
Logic PLC RPDO mapping: Entry 12
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:013
|
Logic PLC RPDO mapping: Entry 13
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:014
|
Logic PLC RPDO mapping: Entry 14
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:015
|
Logic PLC RPDO mapping: Entry 15
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F0:016
|
Logic PLC RPDO mapping: Entry 16
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:000
|
Logic PLC TPDO mapping: Highest subindex
0 ... [0] ... 16
–
Setting can only be changed if the inverter is disabled.
|
|
0x24F1:001
|
Logic PLC TPDO mapping: Entry 1
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:002
|
Logic PLC TPDO mapping: Entry 2
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:003
|
Logic PLC TPDO mapping: Entry 3
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:004
|
Logic PLC TPDO mapping: Entry 4
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:005
|
Logic PLC TPDO mapping: Entry 5
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:006
|
Logic PLC TPDO mapping: Entry 6
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:007
|
Logic PLC TPDO mapping: Entry 7
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:008
|
Logic PLC TPDO mapping: Entry 8
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:009
|
Logic PLC TPDO mapping: Entry 9
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:010
|
Logic PLC TPDO mapping: Entry 10
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:011
|
Logic PLC TPDO mapping: Entry 11
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:012
|
Logic PLC TPDO mapping: Entry 12
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:013
|
Logic PLC TPDO mapping: Entry 13
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:014
|
Logic PLC TPDO mapping: Entry 14
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:015
|
Logic PLC TPDO mapping: Entry 15
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x24F1:016
|
Logic PLC TPDO mapping: Entry 16
0x00000000 ... [0x00000000] ... 0xFFFFFFFF
|
|
0x2634:030
|
Digital outputs function: Logic PLC In bit 0
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 0 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:031
|
Digital outputs function: Logic PLC In bit 1
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 1 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:032
|
Digital outputs function: Logic PLC In bit 2
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 2 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:033
|
Digital outputs function: Logic PLC In bit 3
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 3 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:034
|
Digital outputs function: Logic PLC In bit 4
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 4 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:035
|
Digital outputs function: Logic PLC In bit 5
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 5 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:036
|
Digital outputs function: Logic PLC In bit 6
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 6 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:037
|
Digital outputs function: Logic PLC In bit 7
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 7 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:038
|
Digital outputs function: Logic PLC In bit 8
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 8 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:039
|
Digital outputs function: Logic PLC In bit 9
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 9 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:040
|
Digital outputs function: Logic PLC In bit 10
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 10 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:041
|
Digital outputs function: Logic PLC In bit 11
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 11 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:042
|
Digital outputs function: Logic PLC In bit 12
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 12 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:043
|
Digital outputs function: Logic PLC In bit 13
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 13 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:044
|
Digital outputs function: Logic PLC In bit 14
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 14 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2634:045
|
Digital outputs function: Logic PLC In bit 15
–
For further possible settings, see parameter 0x2634:010.
|
Assignment of a trigger to input bit 15 of the Logic PLC.
Trigger = FALSE: Bit is set to 0.
Trigger = TRUE: Bit is set to 1.
|
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
0x2661:004
|
Logic PLC inputs: Value 1 selection
|
Selection of the signal to be transferred to the Logic PLC as "Value 1".
|
|
0
|
Not active
|
No signal assigned.
|
|
1
|
Output frequency
|
Actual output frequency (resolution: 0.1 Hz).
|
|
2
|
Frequency setpoint
|
Current frequency setpoint (resolution: 0.1 Hz).
|
|
3
|
Analog input 1
|
Input signal of analog input 1 (resolution: 0.1 %).
|
|
4
|
Analog input 2
|
Input signal of analog input 2 (resolution: 0.1 %).
|
|
5
|
Motor current
|
Actual motor current (resolution: 0.1 A).
|
|
6
|
Output power
|
Actual output power (resolution: 0.001 kW).
|
|
7
|
Torque actual value
|
Current torque (resolution: 0.1 %).
–
100 % = permissible maximum torque 0x6072
|
|
8
|
Actual motor frequency
|
Actual motor output frequency (resolution: 0.1 Hz).
|
|
11
|
DC-bus voltage
|
Current DC-bus voltage (resolution: 1 V).
|
|
12
|
Device utilisation (ixt)
|
Current device utilization (resolution: 1 %).
|
|
20
|
NetWordIN3
|
Actual value of the NetWordIN3 data word (resolution: 0.1 %).
|
|
21
|
NetWordIN4
|
Actual value of the NetWordIN4 data word (resolution: 0.1 %).
|
|
210
|
IOL1 AI1 scaled value
|
Value is specified as process data object via IO-Link.
–
The function assignment of the connectors must be configured accordingly.
–
The IO-Link ports are only available on the inverter with Application-I/O.
|
|
211
|
IOL1 AI2 scaled value
|
|
212
|
IOL2 AI1 scaled value
|
|
213
|
IOL2 AI2 scaled value
|
|
214
|
IOL3 AI1 scaled value
|
|
215
|
IOL3 AI2 scaled value
|
|
216
|
IOL4 AI1 scaled value
|
|
217
|
IOL4 AI2 scaled value
|
|
230
|
Scaling1 value
|
Output values of the "Analog signal scaling" function. This function is used to scale internal analog signals (analog parameter values) for use within the inverter.
|
|
231
|
Scaling2 value
|
|
0x2661:005
|
Logic PLC inputs: Value 2 selection
–
For further possible settings, see parameter 0x2661:004.
|
Selection of the signal to be transferred to the Logic PLC as "Value 2".
|
|
0
|
Not active
|
No signal assigned.
|
|
0x2662:001
|
Logic PLC outputs: Output word
0 ... [0] ... 65535
|
Display of the status of the output bits from the Logic PLC.
–
The 16 output bits can also be selected as triggers for certain inverter functions.
|
|
Bit 0
|
Mapping bit 0
|
|
|
Bit 1
|
Mapping bit 1
|
|
Bit 2
|
Mapping bit 2
|
|
Bit 3
|
Mapping bit 3
|
|
Bit 4
|
Mapping bit 4
|
|
Bit 5
|
Mapping bit 5
|
|
Bit 6
|
Mapping bit 6
|
|
Bit 7
|
Mapping bit 7
|
|
Bit 8
|
Mapping bit 8
|
|
Bit 9
|
Mapping bit 9
|
|
Bit 10
|
Mapping bit 10
|
|
Bit 11
|
Mapping bit 11
|
|
Bit 12
|
Mapping bit 12
|
|
Bit 13
|
Mapping bit 13
|
|
Bit 14
|
Mapping bit 14
|
|
Bit 15
|
Mapping bit 15
|
|
0x2662:002
|
Logic PLC outputs: Value 1
0 ... [0] ... 65535
|
Display of the output value "Value 1" from the Logic PLC.
|
|
0x2662:003
|
Logic PLC outputs: Value 2
0 ... [0] ... 65535
|
Display of the output value "Value 2" from the Logic PLC.
|
|
0x2667:001
|
User parameter 16 bit: Entry 1
0 ... [0] ... 65535
|
|
|
Bit 0
|
Mapping bit 0
|
|
Bit 1
|
Mapping bit 1
|
|
Bit 2
|
Mapping bit 2
|
|
Bit 3
|
Mapping bit 3
|
|
Bit 4
|
Mapping bit 4
|
|
Bit 5
|
Mapping bit 5
|
|
Bit 6
|
Mapping bit 6
|
|
Bit 7
|
Mapping bit 7
|
|
Bit 8
|
Mapping bit 8
|
|
Bit 9
|
Mapping bit 9
|
|
Bit 10
|
Mapping bit 10
|
|
Bit 11
|
Mapping bit 11
|
|
Bit 12
|
Mapping bit 12
|
|
Bit 13
|
Mapping bit 13
|
|
Bit 14
|
Mapping bit 14
|
|
Bit 15
|
Mapping bit 15
|
|
0x2667:002
|
User parameter 16 bit: Entry 2
0 ... [0] ... 65535
|
|
0x2667:003
|
User parameter 16 bit: Entry 3
0 ... [0] ... 65535
|
|
0x2667:004
|
User parameter 16 bit: Entry 4
0 ... [0] ... 65535
|
|
0x2667:005
|
User parameter 16 bit: Entry 5
0 ... [0] ... 65535
|
|
0x5811:001
|
Configuration PLC application: Output data at stopped Logic PLC
–
Setting can only be changed if the inverter is disabled.
|
|
0
|
Keep last data
|
|
1
|
Clear data
|
|
0x5811:002
|
Configuration PLC application: Error response on exception
|
Associated event ID:
–
24704 | 0x6080 - Logic PLC exception error
|
|
0
|
No response
|
|
|
11
|
Information
|
|
12
|
Warning
|
|
16
|
Trouble
|
|
23
|
Fault > inverter disabled
|