Diagnostics
Status LEDs
When CIP Safety communication is set, the network status LEDs "MS" and "NS" display CIP Safety status information.
DANGER!
Unreliable status information possible due to LEDs.
LEDs are not reliable status displays. It is not guaranteed that the LEDs provide exact information.
Possible consequences: Death or severe injuries
▶
Only use LEDs for general diagnostics during commissioning or troubleshooting.
 
▶
Do not use LEDs as status displays.
 
 
The "MS" LED indicates the CIP Safety Supervisor State:
LED "MS" (green/red)
CIP Safety
Supervisor State
State/meaning
off
No Power
The device is not supplied with power.
on (green)
Executing
The device is ready for operation and the secure I/O connection has been established.
blinking green
Idle
No IP address or no safe I/O connection.
blinking red
Abort
The device has a rectifiable fault. There is an addressing conflict with the node ID.
on (red)
Critical Fault
The device has a fault that cannot be rectified.
blinking green/red
Device Self-Testing
The device performs a self-test.
The "NS" LED indicates the CIP Safety network status:
LED "NS" (green/red)
CIP Safety-network status
State/meaning
off
No IP address
The network option is not supplied with power or has not yet received an IP address.
on (green)
Connected
The network option is working properly and has established a connection to the originator.
blinking green
No connections
The network option
–
works perfectly,
 
–
has been assigned an IP address,
 
–
has not yet been integrated into the network by the originator.
 
blinking red
Connection Timeout
A timeout has occurred.
on (red)
Duplicate IP
The network option cannot access the network (IP address conflict).
blinking green/red
Device Self-Testing
The network option performs a self-test.
 
Diagnostic parameter
Address
Name / setting range / [default setting]
Information
0x212A:010
S-Bus: CIP Safety - status
–
Read only
 
Display of the current CIP Safety status of the device. Corresponds to Safety Supervisor Object Attribute 11 (Device Status).
0
Undefined
Undefined state
1
Self-Testing
A self-test is performed after switching on.
2
Idle
Self-test successfully completed, a valid configuration is available.
3
Self-Test Exception
Self-test has failed.
4
Executing
At least one safety connection has been established.
5
Abort
A recoverable error has occurred.
6
Critical Fault
A non-recoverable error has occurred. The CIP Safety connections are not processed any further.
0x2134:001
S-Event history CSS: Internal event 1
–
Read only
 
Internal event history from CIP Safety Stack (CSS).
0x2134:002
S-Event history CSS: Internal event 2
–
Read only
 
0x2134:003
S-Event history CSS: Internal event 3
–
Read only