Digital inputs and outputs
The following parameters serve to diagnose the digital inputs and outputs of the inverter.
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x282C:001
|
I/O diagnostic: Application level of the digital inputs
–
Read only
|
This parameter indicates the bit coded state or the digital inputs contain the setting of 0x2632:001 (Digital input 1).
|
|
|
Bit
16
|
Digital input 1
|
||
|
Bit
17
|
Digital input 2
|
||
|
Bit
18
|
Digital input 3
|
||
|
Bit
19
|
Digital input 4
|
||
|
Bit
20
|
Digital input 5
|
||
|
Bit
21
|
Digital input 6
|
||
|
Bit
22
|
Digital input 7
|
||
|
Bit
23
|
Digital input 8
|
||
|
Bit
24
|
Digital input 9
|
||
|
Bit
25
|
Reserved
|
||
|
Bit
26
|
Reserved
|
||
|
Bit
27
|
Reserved
|
||
|
Bit
28
|
Reserved
|
||
|
Bit
29
|
Reserved
|
||
|
Bit
30
|
Reserved
|
||
|
Bit
31
|
Reserved
|
||
|
0x60FD
|
Digital input status
–
Read only
|
Bit coded display of the current status of the digital inputs
|
|
|
Bit
0
|
Reserved
|
-
|
|
|
Bit
1
|
Reserved
|
||
|
Bit
2
|
Reserved
|
||
|
Bit
3
|
Reserved
|
||
|
Bit
16
|
Digital input 1
|
||
|
Bit
17
|
Digital input 2
|
||
|
Bit
18
|
Digital input 3
|
||
|
Bit
19
|
Digital input 4
|
||
|
Bit
20
|
Digital input 5
|
||
|
Bit
21
|
Digital input 6
|
||
|
Bit
22
|
Digital input 7
|
||
|
Bit
23
|
Digital input 8
|
||
|
Bit
24
|
Digital input 9
|
||
|
Bit
25
|
Internal interconnection of digital inputs
|
0 = digital inputs are internally set to HIGH (NPN) level via pull-up resistors.
1 = digital inputs are internally set to LOW (PNP) level via pull-down resistors.
|
|
|
Bit
26
|
Reserved
|
-
|
|
|
Bit
27
|
Reserved
|
||
|
Bit
28
|
Reserved
|
||
|
Bit
29
|
Reserved
|
||
|
Bit
30
|
Reserved
|
||
|
Bit
31
|
|||
Configure digital inputs