User-definable V/f characteristic

The "user-definable V/f characteristic" is provided for the individual adjustment of the motor magnetisation to the actual application if linear and square-law characteristics are not suitable.
–
The characteristic is defined by means of 11 parameterisable grid points (voltage/frequency values).
 
–
In the Lenze setting the 11 grid points represent a linear characteristic:
 
 
 
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P11
V
400 V
320 V
240 V
160 V
80 V
0 V
80 V
160 V
240 V
320 V
400 V
f
-50 Hz
-40 Hz
-30 Hz
-20 Hz
-10 Hz
0 Hz
10 Hz
20 Hz
30 Hz
40 Hz
50 Hz
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2B02:001
Frequency grid points (x) user V/f characteristic: x1 = f01
-5000 ... [-50] ... 5000 Hz
Freely parameterizable V/f characteristic (values for X axis). These settings define the adaptive frequency values.
0x2B02:002
Frequency grid points (x) user V/f characteristic: x2 = f02
-5000 ... [-40] ... 5000 Hz
0x2B02:003
Frequency grid points (x) user V/f characteristic: x3 = f03
-5000 ... [-30] ... 5000 Hz
0x2B02:004
Frequency grid points (x) user V/f characteristic: x4 = f04
-5000 ... [-20] ... 5000 Hz
0x2B02:005
Frequency grid points (x) user V/f characteristic: x5 = f05
-5000 ... [-10] ... 5000 Hz
0x2B02:006
Frequency grid points (x) user V/f characteristic: x6 = f06
-5000 ... [0] ... 5000 Hz
0x2B02:007
Frequency grid points (x) user V/f characteristic: x7 = f07
-5000 ... [10] ... 5000 Hz
0x2B02:008
Frequency grid points (x) user V/f characteristic: x8 = f08
-5000 ... [20] ... 5000 Hz
0x2B02:009
Frequency grid points (x) user V/f characteristic: x9 = f09
-5000 ... [30] ... 5000 Hz
0x2B02:010
Frequency grid points (x) user V/f characteristic: x10 = f10
-5000 ... [40] ... 5000 Hz
0x2B02:011
Frequency grid points (x) user V/f characteristic: x11 = f11
-5000 ... [50] ... 5000 Hz
0x2B03:001
Voltage grid points (y) user V/f characteristic: y1 = U01 (x = f01)
0.00 ... [400.00] ... 1000.00 V
Freely parameterizable V/f characteristic (values for Y axis). These settings define the adaptive voltage values.
0x2B03:002
Voltage grid points (y) user V/f characteristic: y2 = U02 (x = f02)
0.00 ... [320.00] ... 1000.00 V
0x2B03:003
Voltage grid points (y) user V/f characteristic: y3 = U03 (x = f03)
0.00 ... [240.00] ... 1000.00 V
0x2B03:004
Voltage grid points (y) user V/f characteristic: y4 = U04 (x = f04)
0.00 ... [160.00] ... 1000.00 V
0x2B03:005
Voltage grid points (y) user V/f characteristic: y5 = U05 (x = f05)
0.00 ... [80.00] ... 1000.00 V
0x2B03:006
Voltage grid points (y) user V/f characteristic: y6 = U06 (x = f06)
0.00 ... [0.00] ... 1000.00 V
0x2B03:007
Voltage grid points (y) user V/f characteristic: y7 = U07 (x = f07)
0.00 ... [80.00] ... 1000.00 V
0x2B03:008
Voltage grid points (y) user V/f characteristic: y8 = U08 (x = f08)
0.00 ... [160.00] ... 1000.00 V
0x2B03:009
Voltage grid points (y) user V/f characteristic: y9 = U09 (x = f09)
0.00 ... [240.00] ... 1000.00 V
0x2B03:010
Voltage grid points (y) user V/f characteristic: y10 = U10 (x = f10)
0.00 ... [320.00] ... 1000.00 V
0x2B03:011
Voltage grid points (y) user V/f characteristic: y11 = U11 (x = f11)
0.00 ... [400.00] ... 1000.00 V