Set slip compensation

The speed of an asynchronous motor decreases as load is applied. This load-dependent speed drop
is called “slip”. The slip compensation serves to counteract the load-dependent speed loss.
 
Observe correct parameterisation of the rated motor frequency 0x2C01:005 and the rated motor speed 0x2C01:004. Both parameters serve to calculate the rated motor slip.
 
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2B09:001
Slip compensation: Gain
-200.00 ... [0.00] ... 200.00 %
Adjustment in percent of the slip calculated.
–
 For instance required for deviations of the real motor data from the nameplate data.
 
–
A setting of 100 % corresponds to the rated slip of the machine in the nominal operating point.
 
0x2B09:002
Slip compensation: Filter time
1 ... [2000] ... 6000 ms
Filter time for the slip compensation.