Position controller
Equation for calculating the gain
The automatic calculation is made via the parameter 0x2822:015 = 1.
|
Parameter
|
Symbol
|
Description
|
Dimension unit
|
|
Vp
|
Position controller gain
|
Hz
|
|
|
0x2985:001 ... 0x2985:011
|
Vp(n)
|
Speed-dependent Vp adaptation
|
|
|
TFilter
|
Filter time constant - actual speed value
|
s
|
|
|
-
|
Tcurrent controller
|
Equivalent time constant of the current control loop = 0.0005 s
(500 µs) |
s
|
Instability of the position control loop due to too high dynamic performance of the speed controller
The following countermeasure must be taken if the following error cannot be reduced to acceptable values while setting the position controller:
1.
Reduce speed controller by the factor 2 and slowly increase the position controller until it gets slightly unstable again.
2.
Reduce the position controller slightly and increase the speed controller until the position control loop gets slightly unstable again.
3.
Repeat these steps until the following error is reduced to acceptable values.
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2822:015
|
Axis commands: Calculate position controller parameter
|
Automatic calculation of the position controller parameters.
|
|
|
0
|
Off/Ready
|
||
|
1
|
On/Start
|
||
|
2
|
In progress
|
||
|
3
|
Action cancelled
|
||
|
4
|
No access
|
||
|
5
|
No access (Device disabled)
|
||
|
0x2980
|
Position controller gain
0.00 ... [28.40] ... 10000.00 1/s
|
Setting of the position controller gain.
|
|
|
0x2981
|
Position controller gain adaption
0.00 ... [100.00] ... 200.00 %
|
Setting of the percentage adaptation for the position controller gain.
|
|
|
0x2982
|
Position controller output signal limitation
0.00 ... [480000.00] ... 480000.00 rpm
|
Setting of the output signal limitation.
|
|
|
0x2983
|
Actual position start value
-2147483647 ... [0] ... 2147483647
|
Specifying a new actual position.
|
|
|
0x2984
|
Mode for setting the actual position
|
Selection of the mode for setting or shifting the actual position.
|
|
|
0
|
Absolute
|
Actual position = Actual position start value (0x2983)
|
|
|
1
|
Relative
|
Actual position = actual position + Actual position start value (0x2983)
|
|
|
0x2985:001
|
Gain characteristic adaptions: Speed setpoint 1
1 ... [10] ... 50000 rpm
|
Characteristic for speed-dependent adaptation of the P gain of the position controller.
|
|
|
0x2985:002
|
Gain characteristic adaptions: Gain adaption 1
1 ... [100] ... 200 %
|
||
|
0x2985:003
|
Gain characteristic adaptions: Speed setpoint 2
1 ... [100] ... 50000 rpm
|
||
|
0x2985:004
|
Gain characteristic adaptions: Gain adaption 2
1 ... [100] ... 200 %
|
||
|
0x2985:005
|
Gain characteristic adaptions: Speed setpoint 3
1 ... [1000] ... 50000 rpm
|
||
|
0x2985:006
|
Gain characteristic adaptions: Gain adaption 3
1 ... [100] ... 200 %
|
||
|
0x2985:007
|
Gain characteristic adaptions: Speed setpoint 4
1 ... [2000] ... 50000 rpm
|
||
|
0x2985:008
|
Gain characteristic adaptions: Gain adaption 4
1 ... [100] ... 200 %
|
||
|
0x2985:009
|
Gain characteristic adaptions: Speed setpoint 5
1 ... [5000] ... 50000 rpm
|
||
|
0x2985:010
|
Gain characteristic adaptions: Gain adaption 5
1 ... [100] ... 200 %
|
||
|
0x2985:011
|
Gain characteristic adaptions: Gain characteristic adaption on/off
|
Switch on/off the gain characteristic adaptation.
–
0 = off
–
1 = on
|
|
|
0
|
Off
|
||
|
1
|
On
|
||
|
0x2986
|
Resulting gain adaption
–
Read only: x.xx %
|
Display of the resulting gain after being adapted.
|
|