Monitoring

Monitoring of the master/slave functionality
The following scenarios are monitored:
–
The inverter at position  1 is not configured as system bus master.
 
–
Several inverters have been configured as system bus master.
 
Depending on the assignment of the system bus interfaces X246 (EtherCAT IN) and X247 (EtherCAT OUT) and the set interface role in 0x2371:009 (master/slave), a warning is output:
Network cable plugged in X246/X247
(Slave)
(Master)
Only X246 (EtherCAT IN) is assigned.
OK
Warning
Only X247 (EtherCAT OUT) is assigned.
Warning
OK
X246 (EtherCAT IN) and X247 (EtherCAT OUT) are assigned.
OK
Warning
 
The parameters for setting network monitoring functions are described below.
 
Parameter
Address
Name / setting range / [default setting]
Information
0x285B:001
onboard EtherCAT monitoring: Watchdog elapsed
Associated event ID:
–
805405057 | 0x30018181 - EtherCAT - Communication error
 
0
No response
1
Fault > CiA402
2
Warning
0x285B:002
onboard EtherCAT monitoring: EtherCAT role check
Reaction if the setting in 0x2371:009 (Master/Slave) and the assignment of X246 (EtherCAT IN)/X247 (EtherCAT OUT) are not plausible.
0
No response
1
Fault > CiA402
2
Warning