0x2A-AC Drive Object
The "AC Drive Object" describes the device-specific functions of the inverter, e.g. speed ramps, torque control etc.
|
Attribute ID
|
Name
|
Info / parameter
|
|
3
|
AtReference
|
Status Signals 0x5030:110: Bit 7 (Setpoint reached)
|
|
4
|
NetRef
|
Control signals 0x5030:010: Bit 6 (Activate network setpoint)
|
|
6
|
DriveMode
|
AC Drive Mode 0x5020:027
–
0 = Vendor specific
–
1 = Speed control (Open Loop)
–
2 = Speed control (Closed Loop)
–
3 = Torque control
|
|
7
|
SpeedActual / 2SpeedScale [rpm]
|
Network actual speed (scaled) = 0x5030:122/20x5030:028
|
|
8
|
SpeedRef / 2SpeedScale [rpm]
|
Network setpoint speed (scaled) = 0x5030:021/20x5030:028
|
|
11
|
TorqueActual / 2TorqueScale [Nm]
|
Network actual torque (scaled) = 0x5030:123/20x5030:029
|
|
12
|
TorqueRef / 2TorqueScale [Nm]
|
Network setpoint torque (scaled) = 0x5030:022/20x5030:029
|
|
18
|
AccelTime
|
Acceleration time 0x5031:190
|
|
19
|
DecelTime
|
Deceleration time 0x5031:191
|
|
20
|
LowSpdLimit
|
Speed - Low limit 0x5031:193
|
|
21
|
HighSpdLimit
|
Speed - High limit 0x5031:192
|
|
22
|
SpeedScale
|
Speed scale value 0x5030:028
Scaling of SpeedActual and SpeedRef.
|
|
24
|
TorqueScale
|
Torque scale value 0x5030:029
Scaling of TorqueActual and TorqueRef.
|
|
29
|
RefFromNet
|
Status Signals 0x5030:110: Bit 6 (Network setpoint active)
|