0x04-Assembly Object

The inverter contains EtherNet/IP assembly object instances which refer to the following »RSLogix™ 5000«connection parameters:
–
Inputs (actual value such as actual speed, actual position, etc.)
 
–
Outputs (enable and reference value for the drive)
 
–
Configuration
 
The inputs and outputs refer to the view of the Scanner (PLC).
Output data/assemblies are created by the Scanner (PLC) and transmitted to the Adapter (inverter).
Input data/assemblies are created by the Adapter (inverter) and transmitted to the Scanner (PLC).
 
The assembly object instances can be accessed via "Class 1 Messaging" (Implicit Messaging) and "Class 3 Messaging" (Explicit Messaging).
See also:
Process data transfer  (Implicit Messaging)
Parameter data transfer  (Explicit Messaging)
The assembly object provides the following common services for accessing Assembly Object instances:
–
0x0E: Get_Attribute_Single (read parameter/assembly data)
 
–
0x10: Set_Attribute_Single (write parameter/assembly data)
 
Predefined assembly object instances can be used according to the "CIP™ Network Library":
 
Assembly output objects (outputs)
Assembly output objects are used to enable the inverter (Adapter) and to specify a speed setpoint or torque setpoint.
Depending on the data length defined by the PLC (Scanner) the memory map of the I/O data may vary in size.
Assembly output objects are assumed to have a 32-bit Run/Idle header. When mapping assemblies, this header is automatically inserted into the data flow by most Allen-Bradley PLC/SLC devices. This does not require any adaptations.
If your PLC does not support the 32-bit Run/Idle header, add a leading 32-bit header to the output image. Set the data in the header to 0.
Bit 0 of the header can be defined in the process image of your PLC:
–
Status 0: Idle mode
 
–
Status 1: Run mode
 
 
Assembly input objects (inputs)
Assembly input objects are usually used to monitor the status of the inverter (Adapter) and to query current actual values (e.g. the current speed).
The input objects are mapped in the Adaptermemory from byte 0 and transmitted "modeless".
The inverter does not use a 32-bit header for the real time status. Thus, the start address in the assembly memory map is the real start of the first assembly data element.
 
Assembly object instances for "AC Drive Profile" technology application
(0x4000 = 5)
 
Output objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
20
(0x14)
0
FaultRst
RunFwd (CW)
1
2
Speed Reference (low byte)
3
Speed Reference (high byte)
21
(0x15)
0
NetRef
NetCtrl
FaultRst
RunRev (CCW)
RunFwd (CW)
1
2
Speed Reference (low byte)
3
Speed Reference (high byte)
22
(0x16)
0
FaultRst
RunFwd (CW)
1
2
Speed Reference (low byte)
3
Speed Reference (high byte)
4
Torque Reference (low byte)
5
Torque Reference (high byte)
23
(0x17)
0
NetRef
NetCtrl
FaultRst
RunRev (CCW)
RunFwd (CW)
1
2
Speed Reference (low byte)
3
Speed Reference (high byte)
4
Torque Reference (low byte)
5
Torque Reference (high byte)
Input objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
70
(0x46)
0
Running1 (Fwd, CW)
Faulted
1
2
Speed Actual (low byte)
3
Speed Actual (high byte)
71
(0x47)
0
AtReference
RefFromNet
CtrlFromNet
READY
Running2 (Rev, CCW)
Running1 (Fwd, CW)
Warning
Faulted
1
Drive State
2
Speed Actual (low byte)
3
Speed Actual (high byte)
72
(0x48)
0
Running1 (Fwd, CW)
Faulted
1
2
Speed Actual (low byte)
3
Speed Actual (high byte)
4
Torque Actual (low byte)
5
Torque Actual (high byte)
73
(0x49)
0
AtReference
RefFromNet
CtrlFromNet
READY
Running2 (Rev, CCW)
Running1 (Fwd, CW)
Warning
Faulted
1
Drive State
2
Speed Actual (low byte)
3
Speed Actual (high byte)
4
Torque Actual (low byte)
5
Torque Actual (high byte)
 
Assembly object instances for "User" technology application
(0x4000 = 10000)
Output objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
110
(0x6E)
0 ... 63
Lenze TA User Output
Input objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
111
(0x6F)
0 ... 63
Lenze TA User Input
 
Assembly object instances for standard technology applications (generic selection)
Output objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
112
(0x70)
0 ... 32
Lenze TA Standard Output
Input objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
113
(0x71)
0 ... 63
Lenze TA Standard Input
 
Assembly object instances for "Speed Control" technology application
(0x4000 = 10)
 
Output objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
134
(0x86)
0 ... 3
Control signals 0x5030:010
4 ... 7
External velocity override 0x5030:011
8 ... 11
External velocity 0x5030:012
12 ... 15
External velocity offset 0x5030:013
16 ... 19
External acceleration 0x5030:014
20 ... 23
External deceleration 0x5030:015
24 ... 27
External jerk 0x5030:016
28 ... 31
External torque limit 0x5030:017
Input objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
135
(0x87)
0 ... 3
Status signals 0x5030:110
4 ... 7
Status signals limiter 0x5030:111
8 ... 11
Actual velocity 0x5030:112
12 ... 15
Status word 3 (reserved) 0x5030:113
16 ... 19
Error code 0x5030:114
20 ... 23
Actual torque 0x5030:115
24 ... 27
Display value 1 0x5030:116
28 ... 31
Display value 2 0x5030:117
 
Assembly object instances for "Table Positioning" technology application
(0x4000 = 20)
 
Output objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
136
(0x88)
0 ... 3
Control signals 0x5030:010
4 ... 7
External velocity override0x5030:011
8 ... 11
External velocity0x5030:012
12 ... 15
External set position 0x5030:023
16 ... 19
External acceleration0x5030:014
20 ... 23
External deceleration0x5030:015
24 ... 27
External jerk0x5030:016
28 ... 31
External torque limit0x5030:017
Input objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
137
(0x89)
0 ... 3
Status signals 0x5030:110
4 ... 7
Status signals limiter0x5030:111
8 ... 11
Actual velocity0x5030:112
12 ... 15
Actual position0x5030:123
16 ... 19
Error code0x5030:114
20 ... 23
Actual torque0x5030:115
24 ...27
Display value 10x5030:116
28 ... 31
Display value 20x5030:117
 
Assembly object instances for "Electronic Gearbox" technology application
(0x4000 = 40)
 
Output objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
138
(0x8A)
0 ... 3
Control signals 0x5040:010
4 ... 7
Control word 1 (reserved) 0x5040:011
8 ... 11
Control word 2 (reserved) 0x5040:012
12 ... 15
External velocity offset 0x5040:013
16 ... 19
Control word 4 (reserved) 0x5040:014
20 ... 23
Control word 5 (reserved) 0x5040:015
24 ... 27
External base velocity 0x5040:016
28 ... 31
External torque limit 0x5040:017
Input objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
139
(0x8B)
0 ... 3
Status signals 0x5040:110
4 ...7
Status signals limiter 0x5040:111
8 ... 11
Actual velocity 0x5040:112
12 ... 15
Actual Position 0x5040:113
16 ... 19
Error code 0x5040:114
20 ... 23
Actual torque 0x5040:115
24 ... 27
Display value 1 0x5040:116
28 ... 31
Display value 2 0x5040:117
 
Assembly object instances for "Sync and Correction" technology application
(0x4000 = 41)
 
Output objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
140
(0x8C)
0 ... 3
Control signals 0x5040:010
4 ... 7
Control word 1 (reserved) 0x5040:011
8 ... 11
Control word 2 (reserved) 0x5040:012
12 ... 15
External position offset 0x5040:023
16 ... 19
Control word 4 (reserved) 0x5040:014
20 ... 23
Control word 5 (reserved) 0x5040:015
24 ... 27
External base velocity 0x5040:016
28 ... 31
Control word 7 (reserved) 0x5040:027
Input objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
141
(0x8D)
0 ... 3
Status signals 0x5040:110
4 ... 7
Status signals limiter0x5040:111
8 ... 11
Actual velocity0x5040:112
12 ... 15
Free Status Word 03 (0x5040:113)0x5040:113
16 ... 19
Error code0x5040:114
20 ... 23
Actual torque0x5040:115
24 ... 27
Display value 10x5040:116
28 ... 31
Display value 20x5040:117
 
Assembly object instances for "Winder Dancer" technology application
(0x4000 = 50)
 
Output objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
142
(0x8E)
0 ... 3
Control signals 0x5050:010
4 ... 7
Set diameter 0x5050:011
8 ... 11
Set velocity 0x5050:012
12 ... 15
Dancer set position 0x5050:023
16 ... 19
Dancer control influence 0x5050:024
20 ... 23
Actual dancer position 0x5050:025
24 ... 27
Control word 6 (reserved) 0x5050:016
28 ... 31
Control word 7 (reserved) 0x5050:017
Input objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
143
(0x8F)
0 ... 3
Status signals 0x5050:110
4 ... 7
Status signals limiter 0x5050:111
8 ... 11
Actual velocity 0x5050:112
12 ... 15
Actual position 0x5050:113
16 ... 19
Error code 0x5050:114
20 ... 23
Actual diameter 0x5050:115
24 ... 27
Display value 1 0x5050:116
28 ... 31
Display value 2 0x5050:117
 
Assembly object instances for "Winder Tension" technology application
(0x4000 = 51)
 
Output objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
144
(0x90)
0 ... 3
Control signals 0x5050:010
4 ... 7
Set diameter0x5050:011
8 ... 11
Set velocity0x5050:012
12 ... 15
Set tension 0x5050:013
16 ... 19
Tension control influence 0x5050:014
20 ... 23
Actual tension 0x5050:015
24 ... 27
Control word 6 (reserved)0x5050:016
28 ... 31
Control word 7 (reserved)0x5050:017
Input objects
Attribute
(Instance ID)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
145
(0x91)
0 ... 3
Status signals 0x5050:110
4 ... 7
Status signals limiter0x5050:111
8 ... 11
Actual velocity0x5050:112
12 ... 15
Actual position0x5050:113
16 ... 19
Error code0x5050:114
20 ... 23
Actual diameter0x5050:115
24 ... 27
Display value 10x5050:116
28 ... 31
Display value 20x5050:117