Identifying the maximum moment of inertia

The maximum motor speed Moment of inertia identification ‐ max. velocity is to be parameterised such that the maximum permissible circumferential speed of the winder is not exceeded. The manufacturer recommends setting the value to 25 %.0x5051:115
The moment of inertia is determined with a rising FALSE-TRUE edge
↗
at the parameter Identify moment of inertia or the parameter Control signals Bit 31.
–
Identify moment of inertia 0x5051:117
 
–
Control signals 0x5050:010 bit 31
 
The active identification run is displayed in the parameter Status signals bit 30 = TRUE and via the parameter Technology application state under Identification of inertia.  
–
Status signals bit 30 = TRUE 0x5050:110
 
–
Technology application state 0x5051:001
 
 
Relevant parameters of other functions
Address
Name
Default setting
Setting range
Moment of inertia identification - max. velocity
20.00 %
1.00 ... 100.00 %
Identify moment of inertia
0