Declutching the cross cutter

The declutch process with xSyncIn input = FALSE can only be carried out if the master axis is moving. Its start is controlled by its position (by a 5th degree polynomial) after the synchronous phase. The cross cutter is hereby stopped in the parking position.

An ongoing declutch process is indicated via the xAccDecSync output = TRUE. After successful declutching, the xAccDecSync output = FALSE and the TM switches to the STANDBY state.

Inputs relevant for the function

  • xSyncIn

Outputs relevant for the function

  • xAccDecSync

Example

Declutching from the cutting process

No

xSyncIn

xSynchronised

INFO

1

FALSE ä TRUE

TRUE

The declutch process is requested

2

FALSE

TRUE æ FALSE

The declutch process is executed

3

FALSE

FALSE

The slave axis is stopped in the parking position; its state changes to "STANDSTILL"