Gearbox factor correction Master value correction

Changing register properties (e.g. within a paper roll) lead to a changed real register length. The difference with respect to the parameterized register length ( scPar.lrSensorToolDistMaster ) leads in turn to corrections in always the same direction (positive or negative). This is inefficient and contributes to increased energy consumption and an increased mechanical load. In this case, the gearbox factor correction calculates the optimum speed setpoint of the master value.

The correction value is determined from the mean value of the detected position errors. This correction value affects the setpoint speed of the master value axis. Through adjustment of the gearbox factor the constant portion of the position errors is eliminated and the corrections are made equally in the positive and negative directions.

The gearbox factor correction is activated when the xGearFactorCorr input = TRUE.

The scPar.lrGearFactorCorrGainMaster parameter is used to set the gearbox factor correction gain factor, which determines how quickly a constant position error is corrected.

Caution: If the selected gain is too high, the setpoint speed may build up.

When the gearbox factor correction is activated, the current value of the corrected gearbox factor is output via the scSignalFlow.lrAverageGearFactorCorr signal flow variable.

The scPar.lrMaxGearFactorCorrMaster parameter is used to define the maximum gearbox factor correction value in master value axis units.

As soon as the optimum corrected gearbox factor has been detected, correction movements occur both in positive and negative direction. The detected gearbox factor value can be permanently accepted when the xGearFactorCorrHold input = TRUE. The value will only be changed when xGearFactorCorrHold is set to FALSE.

Inputs relevant for the function

  • xGearFactorCorr

  • xGearFactorCorrHold

Outputs relevant for the function

  • lrGearFactorCorr

Parameters relevant for the function

  • scPar.lrGearFactorCorrGainMaster , initial value: 0.1

  • lrMaxGearFactorCorrMaster , initial value: 10

Signal flow structures relevant for the function

  • scSignalflow.MP_xGearFactorCorrLimited

Example: 1

"Activate gearbox factor correction" signal characteristic

No

xGearFactorCorr

INFO

1

FALSE ä TRUE

The gearbox factor is corrected. At the end of the process, the mean mark error = 0 units.

Example 2

"Maintain optimized gearbox factor" signal characteristic

No

xGearFactorCorrHold

INFO

1

FALSE ä TRUE

The detected gearbox factor is maintained. There is no further gearbox factor calculation due to newly occurring mark errors.