AutoTuning

For setting up the control of a servo drive, Lenze offers the AutoTuning function. This function automatically sets the gain factors of the speed and motor angle control as well as the integral component of the speed control (Link to L_MC1P AutoTuning).

For mechanically coupled drives, AutoTuning for single axes cannot be used; a special AutoTuning for coupled axes is used instead. The sequence of the controller optimization for the main axis and the following axis can be selected via subindex 170 (Auto-Tuning: Sequence) of the single-axis kinematics.

Since the controllers are set based on the determined stability limit, the mechanics must be brought into the state in which the controllers are relieved the most before optimization. The lowest stability limit is to be expected there.

For mechanically uncoupled followers or soft gantry applications, the axes must be decoupled manually and AutoTuning for single axes must be applied.

The following modes are available:

  • [0] 1st main axis, 2nd following axis (default)

  • [2] Simultaneously

[0] Mode “1st main axis, 2nd following axis” (subindex 170 = 0)

  • AutoTuning is started via subindex 170 of the main axis.

  • The setpoint generation is performed by the main axis.

Step 1 (AutoTuning main axis):

  • In the 1st step, AutoTuning is performed for the main axis.

  • The following axis follows in the mode parameterized in subindex 35 of the coupling element.

  • The AutoTuning sequence essentially corresponds to the AutoTuning function for single axes (see Auto-Tuning).

  • The controller parameters are only changed in the main axis.

Step 2 (Auto-Tuning following axis):

  • After AutoTuning of the main axis has completed successfully, AutoTuning is performed for the following axis.

  • In this AutoTuning, the setpoint generation is performed via the main axis.

  • The profile parameters for the AutoTuning of the main axis are also used (subindex 171-173 of the motion axis).

  • The following axis follows the mode parameterized in subindex 35 of the coupling element.

  • The controller parameters are only changed in the following axis.

  • Only the controller cascades active for the coupling mode are optimized.

Step 3 (Completion of AutoTuning):

  • After AutoTuning has completed for the main axis and the following axis, AutoTuning for the single-axis kinematics is completed.

  • The result of the entire AutoTuning process is output in the AutoTuning state (subindex 177 of the main axis).

[2] Mode “simultaneously” (subindex 170 = 2)

  • AutoTuning is started via subindex 170 of the main axis.

  • The AutoTuning sequence essentially corresponds to the AutoTuning function for single axes (see Auto-Tuning).

  • The setpoint generation is performed by the main axis

  • The controller parameters are changed simultaneously in both coupled axes, regardless of the parameterized coupling type, and are parameterized identically.

  • This mode can be used for identical drive trains (motor, kinematics and feedback system).

  • After AutoTuning has completed, the result is output in the AutoTuning state of the main axis (subindex 177).