Homing / Set position
-
The homing parameters of the respective motion axes apply for homing
-
The execution sequence for the homing run is defined via subindex 40 (Homing: Sequence) of the coupling element (gantry node)
-
If homing is started while coupling is activated, the main axis and the following axis are automatically homed according to the set sequence.
-
Only when the homing runs of both axes and a parameterized alignment are completed, the main axis reports “HomingDone” and changes to the “Standstill” state.
-
During homing, the following axis also changes to the “Homing” state
-
A MC_SetPosition only acts on the axis connected to the Axis input
-
If the single-axis kinematics (gantry node) is enabled, a MC_SetPosition on the following axis is not possible.
-
A design-related position offset between main and following axis can be taken into account via subindex 36. It remains valid after homing as well